Search filter

130 results found

Schulpraktika technisch

Schulpraktika technisch

Internship | Other | Leonberg

GC 304 R technical drawing
Product scale drawing

GC 304 SF technical drawing
Product scale drawing

GC 304 R technical drawing
Product scale drawing

GC 304 R technical drawing

(DWG | 140 KB)
GC 304 SF technical drawing
Product scale drawing

GC 304 SF technical drawing

(DWG | 140 KB)
GC 304 R technical drawing
Product scale drawing

GC 304 R technical drawing

(DOCUMENT | 525 KB)
GC 304 SF technical drawing
Product scale drawing

GC 304 SF technical drawing

(DOCUMENT | 527 KB)
Technical data GEZE ActiveStop
Flyer/folder

New door control in detail. Information about GEZE ActiveStop. GEZE Act i veStop INTEG R ATE D GEZE Act i veStop SUR FACE-M OU N TE D - TIM B E R D O O R GEZE Act i veStop SUR FACE-M OU N TE D - G L ASS DO O R activestop.geze.com/en 2020_05 ID no. 164543 EN Subject to changes Technical data AREAS OF AP P L I CAT ION GEZE ActiveStop integrated GEZE ActiveStop surface-mounted Door type Timber interior doors, rebated and flush-mounted Timber interior doors, rebated and flushmounted; glass interior doors with timber frames Note: special accessories are needed for satin glass Leaf weight optimal function up to 45 kg optimal function up to 45 kg Leaf width optimal function up to 1100 mm optimal function up to 1100 mm Leaf thickness from 38 mm for wood: at least 12 mm Lintel depth for glass: at least 29 mm Door hinge for DIN left and DIN right for DIN left and DIN right Installation type concealed fitted on the leaf, glass: opposite hinge side, wood: hinge side Rebate between door leaf and frame, approx. … mm clearance in handle area P RO D UCT FEAT URES Damping and closing closing direction – starting from approx. 25° opening direction – starting from approx. 60° closing direction – starting from approx. 25° opening direction – starting from approx. 60° Free swing area freely selectable door position – between 25° and 60° freely selectable door position – between 25° and 60° Door opening angle with variable adjustment – between 80° and 140° with variable adjustment – between 80° and 140° (wood) or 110° (glass) Damping strength can be set using a valve can be set using a valve Protection against overload with integrated safety valve with integrated safety valve Low-maintenance designed for maintenance-free operation in private room doors designed for maintenance-free operation in private room doors O RD ERING INFORM ATION Source hardware dealers or pre-mounted door leaves and frames from specialist door dealers hardware dealers or online via activestop.geze.com/en Order number 163411 (ready-to-install complete set in silver) 184105 glass – simulated stainless steel 184091 glass – silver 184103 glass – white RAL 9016 184102 wood – silver 184104 wood – white RAL 9016 184106 wood – simulated stainless steel Other RAL colours available on request. GEZE ActiveStop, guide rail with sliding block and end buffer, connection handle, universal door latch block, installation material GEZE ActiveStop, guide rail with sliding block and end buffer, connection handle, universal door latch block, installation material, design cover 165814 Fixing plates for guide rails 166886 Milling fixture 169725 Milled edge cover RAL 7035 169724 Milled edge cover RAL 9016 179624 Milled edge cover as per RAL 184109 Fastening set for special glass Scope of delivery Accessories

GEZE wireless programme window technology 24 V
Installation instructions

3 Wireless program 24 V window drives … 1 … GEZE wireless program EN Installation and service instructions 24 V window drives … 3 … 4 … Transmitting module WTM (Id. No. 131212) Remote control WTH-2 (ID no. 131210) Remote control WTH-4 (ID no. 131211) Receiving module WRM-24 (ID no. 131213) Receiving module WRM-24B (Id. No. 131214) Vent switch LTA-24-AZ, flush-mounted (Id. No. 129393) e.g. power supply NT 1,5 A-24 V (ID no. 151425) … 4 … 6 … Functional description … “OPEN” / “CLOSE” command X In order to open or close windows press the correspondingly taught push button on the transmitter. … X “STOP” command In order to stop windows during opening or closing press the corresponding opposite button on the transmitter. 195411-07 … Safety notices … Mounting / connection … Connecting the radio transmitter … 2 It is important to follow these instructions for the safety of persons. These instructions must be kept. à Before installation, read and observe the safety notes for these components and the drive. Warranty claims require proper mounting, installation and maintenance in accordance with the manufacturer's specifications. à Only appropriately qualified people may carry out installation, commissioning and maintenance. Unauthorised modifications to the system release GEZE from liability for any resulting damages. à Only use GEZE original parts for repair and service work. à Observe the latest versions of guidelines, standards and countryspecific regulations. à Protect the components of the GEZE wireless program 24 V window drives from construction dirt and water. … Intended use The GEZE wireless program 24 V window drives is used for activating GEZE 24 V window drives. Wire-bound switches and push buttons can be added or replaced. Remote control with wall holder BN … COM … CLOSE GN YE … OPEN LTA-24-AZ Connecting the transmitting module WTM to the vent switch LTA-24-AZ … Connecting the receiving module CLOSE OPEN … In2 In1 Power supply * Optional cabling, if already existing push buttons available Smoke and heat extraction control panel / vent switch … 2 … 4 … 6 … B A Out2 Out1 … 2 … CLOSE OPEN GND 24V Connecting the receiving module WRM-24 to the smoke and heat extraction control panel Power supply * Smoke and heat extraction control panel / vent switch … 2 … 4 … 6 … 6 CLOSE OPEN Set DIP switch before teach-in. See section … . 24V GND DIP Optional cabling, if already existing push buttons available In1 In2 … 1 … 2 OPEN CLOSE … Out1 Out2 A … B To ensure emergency power operation the receiving module may not be supplied battery-buffered from the smoke and heat extraction control panel. Connection of the receiving module to IQ gear … B In2 In1 A Out2 Out1 … Power supply … 2 CLOSE OPEN GND 24V YE, CLOSE GN, OPEN BN, COM+ RD BK IQ gear WH (ID: 151959) YE GN BN WH RD BK … CLOSE OPEN COM Signal 24V GND Teach button The operating mode is set by means of the DIP switch at the receiving module that has to be set correctly before commissioning. DIP DIP switch In1 In2 … 1 … 2 … Out1 Out2 A B DIP switch at the receiving module WRM-24 and WRM-24B Operation without latching: à Activation as long as the wireless key is kept pressed. ON … 2 DIP1 = OFF DIP2 = ON Wireless signal drops after approx. 10 seconds. Smoke and heat extraction control panel or drive resp. must be set to dead man’s operation. Operation with latching: à Activation triggers permanent signal for latching operation. ON … 2 In1 In2 … 1 … 2 … Out1 Out2 A B Teach button at the receiving module WRM-24 and WRM-24B Press the teach button on the receiving module for approx. … second in order to activate teach-in. à The receiving module beeps 1× briefly every … seconds. à The memory for the “Open” function is selected. X Press the corresponding push button for “OPEN” on the radio transmitter briefly within 30 seconds. à The receiving module beeps 1× long as confirmation and then every 2× every … seconds. à The memory for the “Close” function is selected. X Press the corresponding push button for “CLOSE” on the radio transmitter briefly within 30 seconds. à The receiving module beeps 1× long as confirmation. à The receiving module has been taught successfully and terminates teaching mode automatically. If further radio transmitters are to be taught, repeat the steps accordingly. A maximum of 85 radio transmitters can be taught per receiving module. If more than 85 radio transmitters are to be taught, additional receiving modules are to be connected correspondingly. X … Receiving module operating mode DIP … Teaching radio transmitters For safety reasons the radio transmitter can only be taught during the first … minutes after the operating voltage has been switched on at the drive. Connecting the receiving module WRM-24B to the smoke and heat extraction control panel * Commissioning Deleting radio transmitters For safety reasons the radio transmitter can only be deleted during the first … minutes after the operating voltage has been switched on. X Press the teach button at the receiving module for approx. 10 seconds. à The receiving module beeps 1× long as confirmation. à All the taught radio transmitters have been deleted successfully from the memory. Taught radio transmitters can only be overwritten. If a taught radio transmitter is to be deleted, all the taught radio transmitters have to be deleted. … Maintenance / battery change … Remote control The battery service life is designed for approx. 30 000 operations. When the battery power declines, the LED begins to flash during operation. The battery should then be replaced by a new battery A23/MN21/P23GA. … Transmitting module The battery service life is designed for approx. 100 000 operations. When the battery power declines, the LED begins to flash during operation. The battery should then be replaced by a new CR 2032 battery. DIP1 = ON DIP2 = ON The permanent signal drops after 10 minutes. >> … Technical data Frequency: Transmission power: Range: Security: Power supply: Relay contact: Dimensions (W × H × D): IP rating: Storage temperature: Service temperature Humidity: … MHz <10 mW ERP approx. 30 m Rolling code WTH: 12 V, battery A23/MN21/P23GA, 50 mAh WTM: … V, CR2032, 220 mAh WRM-24: 24 V, … mA (current consumption during standby) WRM-24B: 24 V, … mA (current consumption during standby) WRM-24: … outputs 100 mA, 48 V WRM-24B: … outputs 100 mA, 48 V WTH: 78 × 51 × 23 mm WTM: 44 × 30 × 11 mm WRM-24: 52 × 47 × 23 mm WRM-24B: 130 × 80 × 35 mm WTH: IP 54 WTM: IP 20 WRM-24 IP 20 WRM-24B IP 54 –20 to +85 °C … to +50°C max. 95%, non-condensing Declaration of conformity GEZE GmbH hereby declares that the wireless system type GEZE wireless program 24 V window drives complies with the Directives 2014/53/EU and 2011/65/EU. The complete text of the EU Declaration of Conformity is available at the following internet address: www.geze.com For EU countries: In compliance with Directive 2012/19/EU concerning Waste Electrical and Electronic Equipment (WEEE). Germany GEZE GmbH Niederlassung Süd-West Tel. +49 (0) 7152 203 594 E-Mail: leonberg.de@geze.com GEZE GmbH Niederlassung Süd-Ost Tel. +49 (0) 7152 203 6440 E-Mail: muenchen.de@geze.com GEZE GmbH Niederlassung Ost Tel. +49 (0) 7152 203 6840 E-Mail: berlin.de@geze.com GEZE GmbH Niederlassung Mitte/Luxemburg Tel. +49 (0) 7152 203 6888 E-Mail: frankfurt.de@geze.com GEZE GmbH Niederlassung West Tel. +49 (0) 7152 203 6770 E-Mail: duesseldorf.de@geze.com GEZE GmbH Niederlassung Nord Tel. +49 (0) 7152 203 6600 E-Mail: hamburg.de@geze.com GEZE Service GmbH Tel. +49 (0) 1802 923392 E-Mail: service-info.de@geze.com Austria GEZE Austria E-Mail: austria.at@geze.com www.geze.at Benelux GEZE Benelux B.V. E-Mail: benelux.nl@geze.com www.geze.be www.geze.nl GEZE Industries (Tianjin) Co., Ltd. Branch Office Guangzhou E-Mail: chinasales@geze.com.cn www.geze.com.cn Scandinavia – Finland GEZE Scandinavia AB Filial Finland E-Mail: finland@geze.com www.geze.fi GEZE Industries (Tianjin) Co., Ltd. Branch Office Beijing E-Mail: chinasales@geze.com.cn www.geze.com.cn Scandinavia – Latvia GEZE Scandinavia AB Latvijas filiāle E-Mail: latvia@geze.com www.geze.lv France GEZE France S.A.R.L. E-Mail: france.fr@geze.com www.geze.fr Scandinavia – Lithuania GEZE Scandinavia AB Filial Lietu. E-Mail: lithuania@geze.com www.geze.lt Hungary GEZE Hungary Kft. E-Mail: office-hungary@geze.com www.geze.hu Scandinavia – Sweden GEZE Scandinavia AB E-Mail: sverige.se@geze.com www.geze.se Iberia GEZE Iberia S.R.L. E-Mail: info.es@geze.com www.geze.es Scandinavia – Norway GEZE Scandinavia AB avd. Norge E-Mail: norge.se@geze.com www.geze.no India GEZE India Private Ltd. E-Mail: office-india@geze.com www.geze.in Scandinavia – Denmark GEZE Danmark E-Mail: danmark.se@geze.com www.geze.dk Italy GEZE Italia S.r.l E-Mail: italia.it@geze.com www.geze.it Singapore GEZE (Asia Pacific) Pte, Ltd. E-Mail: gezesea@geze.com.sg www.geze.com GEZE Engineering Roma S.r.l E-Mail: italia.it@geze.com www.geze.it South Africa GEZE South Africa (Pty) Ltd. E-Mail: info@gezesa.co.za www.geze.co.za Korea GEZE Korea Ltd. E-Mail: info.kr@geze.com www.geze.com Bulgaria GEZE Bulgaria - Trade E-Mail: office-bulgaria@geze.com www.geze.bg Poland GEZE Polska Sp.z o.o. E-Mail: geze.pl@geze.com www.geze.pl China GEZE Industries (Tianjin) Co., Ltd. E-Mail: chinasales@geze.com.cn www.geze.com.cn Romania GEZE Romania S.R.L. E-Mail: office-romania@geze.com www.geze.ro GEZE Industries (Tianjin) Co., Ltd. Branch Office Shanghai E-Mail: chinasales@geze.com.cn www.geze.com.cn Russia OOO GEZE RUS E-Mail: office-russia@geze.com www.geze.ru Scandinavia – Estonia GEZE Scandinavia AB eesti filial E-Mail: estonia@geze.com www.geze.ee GEZE GmbH Reinhold-Vöster-Straße 21–29 71229 Leonberg Germany Switzerland GEZE Schweiz AG E-Mail: schweiz.ch@geze.com www.geze.ch Türkiye GEZE Kapı ve Pencere Sistemleri E-Mail: office-turkey@geze.com www.geze.com Ukraine LLC GEZE Ukraine E-Mail: office-ukraine@geze.com www.geze.ua United Arab Emirates/GCC GEZE Middle East E-Mail: gezeme@geze.com www.geze.ae United Kingdom GEZE UK Ltd. E-Mail: info.uk@geze.com www.geze.com Tel.: 0049 7152 203 … Fax: 0049 7152 203 310 www.geze.com

GC 304 weather hood technical drawing
Product scale drawing