GC 307+
Swing doors Accessories for swing doors Activation devices and sensor systems Activation Radar movement detectors

GC 307+

Non-contact proximity switch for activating automatic doors

Downloads

WRM-24
Swing doors Accessories for swing doors Activation devices and sensor systems Activation Wireless programme

WRM-24

Receiving module for activating automatic doors and window drives with 24 V DC

Downloads

WRM-24B
Swing doors Accessories for swing doors Activation devices and sensor systems Activation Wireless programme

WRM-24B

Receiving module for activating automatic doors and window drives with 24 V DC

Downloads

Retrofit adapter GC 365 (8->10 poles)
Sliding doors Accessories for sliding doors Activation devices and sensor systems Combined detector GC 365

Retrofit adapter GC 365 (8->10 poles)

For simple and time-saving retrofitting of the sensor on pre-wired door systems

Downloads

Retrofit adapter GC 341 (6->10 poles)
Sliding doors Accessories for sliding doors Activation devices and sensor systems Protection Light curtains GC 341

Retrofit adapter GC 341 (6->10 poles)

For simple and time-saving retrofitting of the sensor on pre-wired door systems

Downloads

Retrofit adapter GC 365/341 (10->10 poles)
Sliding doors Accessories for sliding doors Activation devices and sensor systems Combined detector GC 365

Retrofit adapter GC 365/341 (10->10 poles)

For simple and time-saving retrofitting of the sensor on pre-wired door systems

Downloads

GC 307+
Installation instructions

PULSE mode) Temperature range –20 °C … Range à Adjust according to requirement. à Depends on the direction of movement, size and material/type of object to be detected. Output modus Pulse mode (NO) Pulse mode (NC) Toggle mode (NO) Toggle mode (NC) Recommended for automatic door drives Recommended for switching applications 60 cm On Off On Off Control INPUT Is activated via an external contact. When the contact is closed, the switching behaviour changes (refer also to section “Door control”) and the LED display lights up red. Input 60 cm LED according to DIP switch settings … 9 small > > > > > > > > large 60 cm Output Output configuration Pulse NO Holding time Pulse NC Toggle NO Toggle NC Toggle Pulse frequency frequency If the “output configuration” is set to Pulse (0, … (Restroom) Note: The door can be unlocked at any time via KB. Note: The door also unlocks automatically after the set “Aut. reset” time has elapsed. After 30 minutes, an external warning signal (acoustic or optical) is triggered. *Only possible via the remote control (100061) Troubleshooting Fault The door does not open. LED Possible causes Faulty or no power supply. Elimination X Check the power supply. Range is too small. X X The door remains open. The door remains open after detection/activation. Adjust range. Remove metallic objects in front of the sensor. Check wiring and relay connection. Wired wrong. X The environment is influencing the functional ability of the sensor. X Remove moving objects from near the sensor. Wired wrong. X Wrong output mode. X Check wiring and relay connection. Switch the output mode to pulse mode. Wired wrong. X Check wiring and relay connection. LED is lit LED is not lit Only for EU countries: In compliance with the European guideline 2012/19/EU concerning waste electrical and electronic equipment (WEEE) GEZE GmbH Reinhold-Vöster-Straße 21–29 71229 Leonberg Germany Tel.: +49 (0) 7152 203

GC 306
Installation instructions

PULSE mode) Temperature range -20 °C …  Toggle mode (T) àà Recommended for switch applications. àà The first detection activates the relay output, the next deactivates it. àà With automatic door applications, the door remains open after the first movement detection. Pulse mode (P) àà Recommended for automatic door applications. àà The first detection activates the relay output for a short time (depending on the duration of movement in front of the sensor).      … Fax: 0049 7152 203 310 www.geze.com Adjust range. Remove metallic objects in front of the sensor. Check wiring and relay connection. Wired wrong. XX The environment is influencing the functional ability of the sensor. XX Remove moving objects from near the sensor. Wired wrong. XX Wrong output mode. XX Check wiring and relay connection. Switch the output mode to pulse mode. Wired wrong. XX Check wiring and relay connection.

Program timer SC28.21 pro
User manual

pulse function The time switch is locked; to unlock the device the PIN has to be entered . 9. New Program OK OK OK OK OK OK **At … sec. = Permanent switching status.  Random optionally selectable no / yes 1. To activate the time switch when operated without power supply. 2. To confirm the selection or the entered data. 13. Additional adjustments 14. Pulse Menu Main menu Application Program query Summertime Language To query the programming steps and remaining memory locations The pulse function provides you the opportunity of programming a switching time with a defined duration. As soon as the pulse-duration has expired the time switch switches OFF automatically (the duration of the pulse is up to 59:59 mm:ss). Deletion of switching time(s). The program for all channels, single The programming is carried out like a standard switching time (see point … / 9) with fo llowing differences Program channels and single programming steps within on channel can be Choose Pulse function (9F). deleted. Define the duration of the pulse ( pulstime minute / pulstime second). Program the days of the week Adjustment Adjustment of date and time Program the switching time ( time hour / time minute) Validation: Confirm the blinking summary of the pulse program 15. Programming via NFC (1) 16. Programming via Bluetooth (1) Adjustment Adjustment of the daylight saving time mode (ON/OFF) Adjustment Choice of languages Factory Defaults Adjustment Reset to the state of delivery. Program delete Date-Time Program -> New program -> Channel A/B -> … Program      Counter Options PIN-Code Options Displays the hour counter and pulse counter for each channel and the time switch itself. The time switch can be locked with a 4-digit PIN-Code. The code can be adjusted, activated and deactivated. If you have forgotten the Code please call customer service. Extra switching time: Program -> new program -> channel A/B -> Extra switching time ->

GEZE wireless program automatic
Installation instructions

Pulse command Press the corresponding push button briefly (< … 2 21/23 GND Receiving module operating mode The operating mode is set by means of the DIP switch on the receiving module that has to be set correctly before initial commissioning. DIP switch DIP switch on the receiving module WRM-24 Pulsed operation (see chapter … DIP1 = OFF DIP2 = OFF Pulsed and continuous operation (see chapter