Search filter

19 results found

AS 500
Swing doors Accessories for swing doors Activation devices and sensor systems Activation Switch

AS 500

AS emergency stop switch with glass pane and five interchangeable labels ("Nottaster öffnen", "Notschalter", "Emergency switch", "Tür schließen" and without text)

Downloads

Admission control – with GEZE Counter | GEZE
Discover Topics

Admission control – with GEZE Counter | GEZE

empty, the doors are unlocked. The display at the door switches to green – and indicates to the people waiting that they may now enter the store again. Smart networking and retro-fitting option GEZE Counter Connect is networked and allows the user to perform numerous settings and evaluations in real time. As a result, the operators can conveniently regulate the maximum number of people from their smartphone, view the current capacity and retrieve statistics about the customer flows in different visualisations. GEZE Counter Connect can be installed as a complete solution or as an upgrade to existing systems. It is compatible with all GEZE automatic door systems and with many systems from other manufacturers*. *All GEZE sliding door systems can be fitted with GEZE Counter Connect. The compatibility of third-party products must be checked first. Download the GEZE Counter flyer (PDF | 438 KB) GEZE Counter can be flexibly adjusted to changing regulatory instructions and ensures the continuing operation of retail businesses. Thanks to the automatic entry control, employees can revert to their actual tasks in the branch. Sebastian Krannich, Business Solutions Manager/Product Manager for GEZE Counter Safe admission control with GEZE Counter Come in please! The visual green signal at the automatic door indicates that people may enter the building. © GEZE GmbH Light signal as design object The narrow visual LED signals fit well into the design of automatic door systems. © GEZE GmbH Entry not allowed! The red light shows visitors that it is not currently possible to enter the building. © GEZE GmbH An investment that pays off in the long term General plus point of GEZE Counter: The number of people in a building can be adjusted at any time so that it is “pleasant” for the people inside. The operators can easily set specific upper limits at any time and individually, to prevent the risk of Covid-19 infection due to the store being overfull, for example. Long-term use of GEZE Counter is possible, e.g. in a seasonal or day-specific application. If, for example, a business is understaffed due to personnel shortages, the system can be used to set the maximum number of customers in the store. Finally, the data acquired with GEZE Counter can be evaluated in many ways. This is where smart sales and marketing experts come in to compare customer flows with buying behaviour, or customer flows with the respective time of day. PLANNING INSTALLATION Servisler PLANNING INSTALLATION Servisler Sector-specific full packages GEZE supports you with specific, industry-specific proposals for integrating systems for digital admission control. Whether planning a new door system or checking and expanding an existing system. The full package of services from GEZE consists of: Consulting Development of solutions Project planning Products Installation After-sales service. Our many years of experience in the market and the corresponding know-how speak for themselves in individually developed solutions. Full realisation and maintenance service GEZE offers comprehensive services for the installation and maintenance of systems. Of course, we also keep the corresponding installation instructions available. Comprehensive service from the outset Alongside planning, installation and maintenance of the systems, GEZE also offers you individual advice and services for special solutions. Your demands and needs in terms of the modern implementation of admission control are challenges for us, which we are happy to take on. Products of GEZE Slimdrive Slimdrive SL NT Automatic linear sliding door system with low overall height and clear design line Go to product ECdrive ECdrive T2 Automatic linear sliding door system for doors up to 140 kg leaf weight Go to product Powerdrive Powerdrive PL Automatic linear sliding door system for large and heavy doors of up to 200 kg leaf weight Go to product Related topics Industries | Retail industry Retail industry GEZE solutions for shopping centres offer aesthetics, safety and are an important component in building automation, making buildings more energy-efficient. Read more Swing doors | Access and security | Topics | Security | Access control Access control Modern access control systems electronically regulate who goes where within a building or site, and when. Read more Sliding doors Individual sliding door solutions With our special solution, we turn your ideas of sliding doors for individual architecture or specific applications into reality. We provide complete project-related solutions for you. Read more

Natural ventilation: air exchange for a healthy indoor climate
Discover Topics

Natural ventilation: air exchange for a healthy indoor climate

empty. FIND OUT MORE ABOUT SMART FAÇADES Natural and energy-efficient ventilation In addition to CO2, classrooms or offices with a large number of people also generate a lot of heat. In the summer in particular, solar radiation often heats the room up even more. Natural ventilation can draw unwanted warm air out of the room towards the outside and so let fresh, cooler external air flow in. In the cool night-time period, free ventilation provides natural building climate control. This produces good air quality naturally due to the differences in temperature, without using any energy to supply and cool the air. Intelligent window ventilation makes a significant contribution to energy efficiency Sustainable and energy efficiency are important keywords in building design: How does the indoor climate change in the course of the day? What might summertime thermal insulation look like? And what about night-time cooling? Learn how GEZE window drives enable natural ventilation, solar input and night-time cooling – effectively supporting sustainability goals – through multiple practical examples and simulations. Greater convenience, safety and hygiene thanks to automated windows The risk of viral infections being spread can be higher in closed rooms because of aerosols. Consequently, a sufficient flow of fresh air provided through ventilation is recommended to improve indoor air hygiene. But if windows have to be opened manually, the contact involved can transmit bacteria, germs and viruses. Automated window drives, which can be operated in a non-contact way, increase convenience and safety for users. DISCOVER OUR GEZE SOLUTIONS FOR NATURAL VENTILATION HERE (PDF |

Installation instructions TSA 325 NT revolving door
Installation instructions

empty pipes (approx. 10 m). XX Lay the empty pipe for the cabling of the sensor equipment and power supply of the drive. XX Before filling the hole with screed check whether the corresponding conduits for all the required cables have been laid and the connected floor guide drainage functions. XX Close the drive box with the supplied stainless steel panels. Revolving door TSA 325 NT …    Init sensor for the zero point Opening for the locking system Fixed panel Floor ring Hole for cable penetration Empty pipe D = 20 mm Cable routing     Position of the locking system at the floor ring:

User manual MBZ 300 configuration software 2.8
User manual

Empty textbox Save textbox content... Empty the devices log All the messages available for the control unit are read. Caution: This can take a very long time! Only deletes the display on the software interface. Saves the contents of the fault memory in a file. (.TXT) Deletes the fault memory of the control unit. The log is a circular buffer (the oldest data are overwritten) with sufficient capacity (depending on granularity). Tip: Use the log memory for trouble shooting and for functional test (granularity „Fine“). 14 MBZ 300 Configuration Software

Environmental product declaration (EPD) for glass sliding systems
Environmental declaration

empty runs)

Environmental product declaration (EPD) for glass door hardware
Environmental declaration

empty runs) Installation into the building (A5) Name Material loss Value

User manual MBZ 300 configuration software 3.0
User manual

Empty text box All the messages available for the control unit are read. Please note: This can take a very long time! Only deletes the display on the software interface. Save text box content... Saves the fault memory to a file (.TXT). Empty the control unit Deletes the fault memory of the control unit. The log is a circular buffer (the oldest data are overwritten) with sufficient capacity (depending on granularity). Tip: Use the log memory for trouble shooting and for functional test (granularity “Fine”). Refer also to the chapter “Meaning of the log entries”. Info: The log memory is large enough to comprise around 1500 entries. The setting is irrelevant. 14 Last control unit changes The date and the drive serial number of the computer which made the most recent change are displayed here. The drive serial number is part of the authorisation key. Text for information and comments of this control unit A text describing the control unit can be entered, e.g. what work a service technician has most recently done on the control unit. MBZ 300 Configuration software

User manual MBZ 300 configuration software 3.2
User manual

Empty text box All the messages available for the control unit are read. Please note: This can take a very long time! Only deletes the display on the software interface. Save text box content... Saves the fault memory to a file (.TXT). Empty the control unit Deletes the fault memory of the control unit. The log is a circular buffer (the oldest data are overwritten) with sufficient capacity (depending on granularity). Tip: Use the log memory for trouble shooting and for functional test (granularity “Fine”). Refer also to the chapter “Meaning of the log entries”. Info: The log memory is large enough to comprise around 1500 entries. The setting is irrelevant. Last control unit changes The date and the drive serial number of the computer which made the most recent change are displayed here. The drive serial number is part of the authorisation key. Text for information and comments of this control unit A text describing the control unit can be entered, e.g. what work a service technician has most recently done on the control unit. 15 PM - Power module

GEZE door closer environmental product declaration
Environmental declaration

empty runs) Name Biogenic carbon content in product Biogenic carbon content in accompanying packaging