Search filter
43 results found
Emergency exit systems
Every second counts in an emergency! Safe escape and rescue routes are indispensable in enabling people to leave a building immediately in the event of danger.
GEZE expands social engagement for its 160th anniversary
… America. In addition, the door, window and safety specialist is providing monthly support to the Girls’ fund in order to foster equitable opportunities for girls and boys as they grow.
Emergency exit systems Contents | GEZE EMERGENCY EXIT SYSTEMS Contents Overview … D OOR C ON TR O L U N I TS Connectable TZ 320 series … Connectable TZ 320 stainless steel series 14 T 320 terminal for bi-directional escape routes 20 LOC K IN G E LE M E N TS FTV 320 escape door lock 26 MA 500 holding magnet 30 SYSTE M S OLUT I O N S Emergency exit protection Nursery school solution– flexible and safe entrance and exit control for nursery schools Emergency exit protection Bi-directional emergency exit protection for doors with emergency exit function in both directions. Central control For doors in interlocking door systems 36 38 40 Hospital ward control visualised IN D IV ID UAL C O M P O N E N TS A N D ACCESSO RI ES Key switches 46 Emergency push buttons 49 Emergency exit signs 52 Power supply 53 Indicator lamps and signal horns 56 Synchronising unit 59 O P E R ATIN G E LE M E N TS myGEZE Control 62 myGEZE Visu 64 Accessories 65 … 4 GEZE EMERGENCY EXIT SYSTEMS | Overview APPLICATION TZ 320 Standard cTZ 320 Comfort with IO 420 extension module LOCAL OPERATION / DISPLAY Short-time release (20 s) Short-time release (1 s – infinite) ● ● Cancellation of short-time release with door closed ● ● Retriggering short-time release ● ● ● ● Pre-alarm (60 s) Pre-alarm (1 s – 10 min.) Alarm ● ● Permanent unlocking ● ● FTV 320 escape door lock 3x 3x Emergency exit electric strike type 331 / 332 3x 3x MA 500 holding magnet 2x 2x CONNECTION POSSIBILITIES Danger alarm system emergency unlocking ● ● Indirect activation ● ● Central emergency push button via safety circuit ● ● External key switch ● ● SCT 222 external key switch with … LEDs ●*** ● External emergency push button ● ● T 320 terminal (bi-directional escape route) ● ● Access control (short-time unlocking) ● ● Top lock (short-time unlocking) ● ● Timer (unlocking) external ● ● Timer (unlocking) internal ● ● Burglar alarm system (locking has priority) ● ● Programmable inputs … 7 Programmable outputs … 6 Flashlight / siren / alarm message ●* ● Motor lock ●* ● Lever lock ●* ● Swing door drive ●** ● Signal light controller ●** ● Additional electric strike ●* ● Output of different system states ●* ● Connection to BMS via myGEZE Control ● STANDARD Conform to EN 13637 ● ● Infrared interface for diagnosis, setting of parameters via ST 220 service terminal ● ● Alarm memory ● ● OTHER Integrated interlocking door system control ● ● Network function for fire alarm system, timer, burglar alarm system ● ● ● = yes I * Function can be realised via two freely configurable outputs. There are two outputs available on the TZ 320. If more outputs are required, the TZ 320 Comfort with IO 420 extension module must be used. | ** Two outputs are required for this function. | *** RP 220 relay board ID no. 102355 required. … 7 AC C ESS C ON T RO L A N D SA FE T Y Door control units Rescue routes must be individually adapted for each building – otherwise they are not safe. The door control unit plays an extremely important role in this respect: In normal circumstances, it lets authorised people pass through the door, and in an emergency, it opens for everyone. Use the wide selection of GEZE door control units with fire and danger alarm systems, escape door locks, motor locks and much more to bring your customised safety concept to life. … GEZE EMERGENCY EXIT SYSTEMS | Door control units TZ 320 Door control unit for controlling escape route doors with illuminated emergency exit sign, key switch and power supply ARE AS OF APP L I CAT I O N EN 13637-compliant protection of an emergency exit against unauthorised access Can be used on single and double leaf doors Connectivity via bus enables e.g. interlocking door system control, forwarding of alarms, connection to building management system Can be combined with motor locks and swing door drives Realisation of a bi-directional emergency exit Flush-mounted installation ensures seamless integration into the building PR OD U CT F E AT U R ES Flat impact cover enables fast and safe activation of the illuminated emergency push button in panic situations Coloured terminals simplify installation Three freely configurable inputs and two freely configurable outputs offer numerous possibilities for additional components Number of inputs and outputs can be extended with the IO 420 extension module Illuminated emergency exit sign improves visibility Integrated power supply offers additional flexibility Integrated key switch enables authorised passing through the emergency exit Door control units | GEZE EMERGENCY EXIT SYSTEMS CON N ECTIV ITY P O SSI B LE FO R D O O R CO N TRO L UN I TS - TZ 320 SERI ES Connectivity – this is a top priority in this product series. You can realise complex applications here, because there are a large number of interfaces to other products and systems. These door control units can communicate with each other due to the integrated bus function. Messages can be visualised on a tableau or PC and can be forwarded to higher-ranking building management systems. Your escape route is secured against unauthorised access in any case. At the same time, the integrated emergency push button ensures access in emergency situations. TEC HN ICAL DATA TZ 320 BSN UP TZ 320 BSN AP Width 81 mm 77 mm Height 223 mm 197 mm Depth in flush-mounted sockets 62 mm deep 88 mm Acoustic signal 75 dB 75 dB Number of outputs … 2 Number of inputs … 3 Illuminated yes yes Operating voltage 24 V DC 24 V DC Contact current capacity 30 V / … A 30 V / … A With ribbon cable yes yes Type of installation Flush-mounted Surface-mounted Emergency push button yes yes Visual display yes yes Parameter setting ST 220 service terminal ST 220 service terminal Sabotage contact yes yes IP rating IP30 IP30 Current consumption 130 mA 130 mA Power supply for external devices (24 V DC) 600 mA 650 mA Service temperature -10 °C...+55 °C -10 °C...+55 °C Supply voltage 230 V 230 V Delayed emergency push button no no Cylinder type Euro profile half cylinder Euro profile half cylinder Conform to EN 13637 yes yes … 10 GEZE EMERGENCY EXIT SYSTEMS | Door control units TZ 320 STAN DA R D D O O R C O N T R O L U N I T – SYSTEM STR UCTUR E 230 V AC 50 HZ 230 V AC 50 Hz V GEZE BUS … 2 TS 5000 … MA 500 MST 210 Powerturn Slimdrive EMD GEZE BUS TK FTV 320 BMA EMA BMA … 5 EMA … 4 ZuKo ZuKo TZ 320 SN IQ lock C … 8 TZ 320 SN IQ lock EL … = flashlight I … = signal horn I … = alarm message I … = key switch I … = sensor strip I … = movement detector I … = contact sensor I … = main switch I BMA = fire alarm system I FTV 320 = escape door lock I FS = latch lock I EMA = burglar alarm system I MA 500 = holding magnet I MST 210 = motor lock control I Powerturn / Slimdrive EMD = swing door drive I TK = door contact I TS 5000 = door closer I ZuKo = access control FUNCTION AL D ES CR I P T I O N In the direction of escape, the door is held closed by an additional electrical locking element which is controlled by the door control unit as the central system unit. Authorised passing of the secured door can be by means of external activation devices such as key switches, access control or an intercom. In the direction of escape, authorised passage is also possible by means of the integrated key switch of the door control unit. If the door is to be passed through from the outside, the panic lock must be mechanically unlocked as well. Time monitoring of the door If the door is not closed after the release time for authorised activation has expired, a pre-alarm is triggered to draw attention to the time limit being exceeded. If the pre-alarm time is also exceeded, a door alarm is triggered and has to be acknowledged by the key switch Passing of the door in case of an emergency In case of an emergency, the door can be released at any time via the integrated emergency push button. Visual and acoustic signal transmitters integrated in the door control unit signal unauthorised passing of the door. Central control and visualisation Due to the integrated bus function of the TZ 320, central visualisation and control of the individual doors can take place via myGEZE Control. Bus functions Burglar alarm systems (EMA), fire alarm systems (BMA) or timers (ZSU) can be connected to a door control unit in the bus system. The signals can be forwarded by the bus to all further door control units. Up to five groups are always possible. Note: forwarding the fire alarm system signal is not permitted with EN 13637 conforming control units. Other functions – Permanent unlocking – Locking – Acknowledging an alarm – Emergency unlocking via the fire alarm system Door control units | GEZE EMERGENCY EXIT SYSTEMS Design variants The variant with IQ lock C, a self-locking contact lock in place of the panic lock, offers increased ease of access from the outside by only one operating process. Mechanical unlocking of the lock and release of the emergency exit protection are carried out simultaneously. The lock is unlocked by the Euro profile cylinder via the integrated cylinder contact of the IQ lock C, and a short-time release is executed at the TZ 320 at the same time. The variant with IQ lock EL, a self-locking motor lock combined with swing door drive, offers increased access convenience due to the fully automatic opening of the door after authorised passage. In daytime operation the door control unit can be permanently unlocked so that passage via push button or radar sensor is possible by anyone. At night, the door control unit can be locked so that passage is only possible by authorised persons. In addition, the self-locking feature guarantees the doors are always locked in accordance with insurance requirements. Planning information The TZ 320 is very well equipped with two freely programmable outputs and three programmable inputs. If the requirements make more outputs or inputs necessary, the system TZ 320 Comfort with IO 420 extension module must be used. If, for example, alarm messages are required in addition to a swing door drive, or if other signals have to be forwarded to a central building management system, more than two outputs are necessary. System components – TZ 320 SN AP/UP door control unit – FTV 320 escape door lock – Emergency exit electric strike with latch lock or holding magnet with installation set and door contact Options – Flashlight, signal horn – SCT 220, SCT 222, SCT 320 external key switches – NOT 320 external emergency push button – Uninterrupted power supply (UPS) – T 320 terminal – ST 220 service terminal – IQ lock EL, EM, C, M – Slimdrive EMD, ECturn, Powerturn swing door drives – Extension of the digital inputs and outputs via IO 420 extension module – Connection to BACnet IP via myGEZE Control 11 12 GEZE EMERGENCY EXIT SYSTEMS | Door control units ORD E R IN FOR MAT I O N Designation Switch programme Version TZ 320 BSN door control unit, flush-mounted, EN 13637 Consisting of: a control unit with emergency push button, key switch with Euro profile half cylinder. Emergency exit sign, illuminated, power supply 24 V DC Jung AS 500 Jung LS 990 Gira E2 Gira E2 ID no. white stainless steel anthracite pure white matt 193509 193510 193511 193542 TZ 320 BSN door control unit, surface-mounted , EN 13637 Consisting of: a control unit with emergency push button, key switch with Euro profile half cylinder. Emergency exit sign, illuminated, power supply 24 V DC white aluminium green 193546 193545 TZ 320 BS door control unit, surface-mounted, EN 13637 Consisting of: control unit with emergency push button, key switch with Euro profile half cylinder, illuminated emergency exit sign, operating voltage 24 V DC white aluminium green 193544 193543 Door control unit configuration 199289 TZ 320 UP control unit Control unit with emergency push button impact cover made of transparent plastic 129586 Door control units | GEZE EMERGENCY EXIT SYSTEMS Products TZ 320 BSN door control unit, flush-mounted, EN 13637, Gira E2 pure white matt (193542) TZ 320 BSN door control unit, flush-mounted, EN 13637, Gira E2 anthracite (193511) TZ 320 BSN UP door control unit, EN 13637, Jung AS 500 white (193509) TZ 320 BSN door control unit, surface-mounted, EN 13637 (193545), TZ 320 BS door control unit, surface-mounted, EN 13637 (193543) TZ 320 BSN door control unit, surface-mounted, EN 13637 (193546), TZ 320 BS door control unit, surfacemounted, EN 13637 (193544) TZ 320 UP control unit (129586) TZ 320 BSN UP door control unit, EN 13637, Jung LS 990 stainless steel (193510) 13 14 GEZE EMERGENCY EXIT SYSTEMS | Door control units TZ 320 - stainless steel Door control unit for controlling escape route doors with illuminated emergency exit sign, key switch and power supply AR E AS OF APP L I CAT I O N EN 13637-compliant protection of an emergency exit against unauthorised access Can be used on single and double leaf doors Connectivity via bus enables e.g. interlocking door system control, forwarding of alarms, connection to building management system Can be combined with motor locks and swing door drives Realisation of a bidirectional emergency exit Flush-mounted installation ensures seamless integration into the building PR OD U CT F E AT U R ES Flat impact cover enables fast and safe activation of the illuminated emergency push button in panic situations Coloured connectors facilitate electrical connection Three freely configurable inputs and two freely configurable outputs offer numerous possibilities for additional components Number of inputs and outputs can be expanded using the IO 420 extension module Integrated power supply offers additional flexibility Integrated key switch enables authorised passing through the emergency exit Robust and attractive stainless steel housing Backlighting with LED backlight possible Installation in stainless steel box Door control units | GEZE EMERGENCY EXIT SYSTEMS CON N ECTIV ITY P O SSI B LE FO R D O O R CO N TRO L UN I TS - TZ 320 STAI N LESS STEEL SER I ES The design version of the TZ 320 is covered in high quality stainless steel. Because of this, it is particularly stable and offers increased protection against vandalism. The integrated sabotage protection is triggered once the front plate is removed. The identical designs of the surface-mounted and flush-mounted front plates make the two variants look almost identical. A distinction can only be established on the basis of the somewhat larger dimensions. This makes it possible to have a standardised look throughout a building. These door control units can be equipped with a “backlight” LED display. The LEDs can signal different functions, such as door closed (red) or door open (green), as well as LEDs continuous (green) or alarm (red). TEC HN ICAL DATA TZ 320 BSN stainless steel, flush-mounted socket set EN 13637 TZ 320 BSN stainless steel, flush-mounted socket set EN 13637 TZ 320 BSN stainless steel, surface-mounted set EN 13637 Width 98 mm 98 mm 78 mm Height 260 mm 260 mm 240 mm Depth 11,5 mm 70 mm 70 mm Acoustic signal 75 db 75 db 75 db Number of outputs … pcs. … pcs. … pcs. Number of inputs … pcs. … pcs. … pcs. Illuminated no no no Operating voltage 24 V DC 24 V DC 24 V DC Contact current capacity 30 V / … A 30 V / … A 30 V / … A With ribbon cable yes yes yes Type of installation flush-mounted flush-mounted surface-mounted Emergency push button yes yes yes Visual display yes yes yes Parameter setting ST 220 service terminal ST 220 service terminal ST 220 service terminal Sabotage contact yes yes yes IP rating IP30 IP30 IP30 Current consumption 130 mA 130 mA 130 mA Power supply for external devices (24 V DC) 950 mA 950 mA 950 mA Supply voltage 230 V 230 V 230 V Service temperature -10 - 55 °C -10 - 55 °C -10 - 55 °C Cylinder type Euro profile half cylinder Euro profile half cylinder Euro profile half cylinder Conform to EN 13637 yes yes yes POS ITION OF T H E D O O R C O N T R O L U N I T ACCO R DI N G TO EN … 3 637 90° … 1200 800 … 2 … 1 … 1 = emergency push button I … = direction of escape 600 15 16 GEZE EMERGENCY EXIT SYSTEMS | Door control units STAN DA R D D OOR C O N T R O L U N I T – SYST EM STRUCTURE 230 V AC 50 HZ 230 V AC 50 Hz V GEZE BUS … 2 TS 5000 … MA 500 MST 210 Powerturn Slimdrive EMD GEZE BUS TK FTV 320 BMA EMA BMA … 5 EMA … 4 ZuKo ZuKo TZ 320 SN IQ lock C … 8 TZ 320 SN IQ lock EL … = flashlight I … = signal horn I … = alarm message I … = key switch I … = sensor strip I … = movement detector I … = contact sensor I … = main switch I BMA = fire alarm system I FTV 320 = escape door lock I FS = latch lock I EMA = burglar alarm system I MA 500 = holding magnet I MST 210 = motor lock control I Powerturn / Slimdrive EMD = swing door drive I TK = door contact I TS 5000 = door closer I ZuKo = access control FU NCTION AL D ES CR I P T I O N In the direction of escape, the door is held closed by an additional electrical locking element which is controlled by the door control unit as the central system unit. Authorised passing of the secured door can be by means of external activation devices such as key switches, access control or an intercom. In the direction of escape, authorised passage is also possible by means of the integrated key switch of the door control unit. If someone wants to pass through the door from the outside, the panic lock must be mechanically unlocked as well. Time monitoring of the door If the door is not closed after the release time for authorised activation has expired, a pre-alarm is triggered to draw attention to the time limit being exceeded. If the pre-alarm time is also exceeded, a door alarm is triggered and has to be acknowledged by the key switch. Passing of the door in case of an emergency In case of an emergency, the door can be released at any time via the integrated emergency push button. Visual and acoustic signal transmitters integrated in the door control unit signal unauthorised passing of the door. Central control and visualisation Due to the integrated bus function of the TZ 320, central visualisation and control of the individual doors can take place via the TE 220 control panel or myGEZE Control. Bus functions Burglar alarm systems (EMA), fire detector systems (BMA) or timers (ZSU) can be connected to a door control unit in the bus system. The signals can be forwarded by the bus to all further door control units. Up to five groups are always possible. Note: Forwarding of the fire alarm system signal is not permitted for EN 13637 conforming control units. Other functions – Permanent unlocking – Locking – Acknowledging an alarm – Emergency unlocking via the fire alarm system Door control units | GEZE EMERGENCY EXIT SYSTEMS Design variants The variant with IQ lock C, a self-locking contact lock in place of the panic lock, offers increased ease of access from the outside by only one operating process. Mechanical unlocking of the lock and release of the emergency exit protection are carried out simultaneously. The lock is unlocked by the Euro profile cylinder via the integrated cylinder contact of the IQ lock C, and a short-term release is executed at the TZ 320 at the same time. The variant with IQ lock EL, the self-locking motor lock combined with swing door drive, offers increased ease of access due to the fully automatic opening of the door after authorised passage. In daytime operation the door control unit can be permanently unlocked so that passage via push button or radar sensor is possible by anyone. At night, the door control unit can be locked so that passage is only possible by authorised persons. In addition, the self-locking feature guarantees the doors are always locked in accordance with insurance requirements. Planning information The TZ 320 is very well equipped with two freely programmable outputs and three programmable inputs. If the requirements make more outputs or inputs necessary, the system TZ 320 Comfort or the the IO 420 extension module must be used. If, for example, alarm signals are needed in addition to a swing door drive, or if other signals have to be forwarded to a central building management system, more than two outputs are necessary. System components – TZ 320 SN AP/UP door control unit – FTV 320 escape door lock – Emergency exit electric strike with latch lock or holding magnet with installation set and door contact Options – Flashlight, signal horn – External key switch SCT 220, SCT 222, SCT 320 – NOT 320 external emergency push button – Uninterrupted power supply (UPS) – T 320 eerminal – ST 220 service terminal – IQ lock EL, EM, C, M – Slimdrive EMD, ECturn, Powerturn swing door drives – TE 220 control panel – Connection to BACnet IP via my GEZE Control 17 18 GEZE EMERGENCY EXIT SYSTEMS | Door control units O RDE R IN FOR MAT I O N Designation Version ID no. stainless steel TZ 320 BSN door control unit stainless steel, surface-mounted set, EN 13637 Consisting of: stainless steel front plate surface-mounted, standard, with recess for Euro profile cylinder, stainless steel housing surface-mounted, TZ 320 control unit flush-mounted with emergency, push button SCT 320 key switch, emergency exit sign pre-mounted, SCT design adhesive frame, 24 V DC power supply, output current max. 950 mA, 230 V AC power supply, operating voltage 24 V DC 193506 stainless steel TZ 320 BSN door control unit stainless steel, flush-mounted set, EN 13637 Consisting of: stainless steel front plate flush-mounted, standard, with recess for Euro profile cylinder, stainless steel housing flush-mounted, TZ 320 UP control unit with emergency, push button SCT 320 key switch, emergency exit sign pre-mounted, SCT design adhesive frame, 24 V DC power supply, output current max. 950 mA 230 V AC power supply, 24 V DC operating voltage 193507 TZ 320 BSN stainless steel door control unit, flush-mounted socket set, EN 13637 Consisting of: stainless steel front plate, flush-mounted standard with recess for Euro profile cylinder, white spacer frame, TZ 320 UP control unit with emergency push button, SCT 320 key switch, emergency exit sign pre-mounted, SCT design adhesive frame, 24 V DC power supply Not included: wall fixing screws Output current max. 950 mA, power supply 230 V AC Operating voltage 24 V DC stainless steel 193508 TZ 32x stainless steel housing surface-mounted flush-mounted 155016 155017 Stainless steel front plate, standard EN 13637 Incl. Makrolon panel with pre-mounted emergency exit sign surface-mounted flush-mounted 193550 193552 Stainless steel front plate RFID, EN 13637 With recess for RFID reader, incl. Makrolon panel with pre-mounted emergency exit sign surface-mounted flush-mounted 193551 193553 Door control unit configuration 199289 TZ 320 UP control unit Control unit with emergency push button impact cover made of transparent plastic 129586 ACCES SORIES Spacer frame for stainless steel housing surface-mounted For installation of the door control unit with surface-mounted stainless steel housing 158696 Spacer frame for stainless steel housing surface-mounted For installation of the door control unit with flush-mounted stainless steel front plate in standard flush-mounted sockets 155030 LED-Backlight, GN/RD For optical backlighting of the stainless steel front plate 155031 SCT design adhesive frame, rectangular/round For attachment around the Euro profile cylinder recess on the front plate. 155034 Accessories mains connection Strain relief of the cables, earthing of the V2A housing Connection of the power supply circuit through Wago connector 155035 Door control units | GEZE EMERGENCY EXIT SYSTEMS Products TZ 320 BSN door control unit stainless steel, surface-mounted set, EN 13637(193506) TZ 320 BSN door control unit stainless steel, flush-mounted set, EN 13637 (193507) TZ 320 BSN door control unit stainless steel, flush-mounted socket set, EN 13637 (ID 193508) TZ 32x stainless steel housing surface-mounted (155016) TZ 32x stainless steel housing flush-mounted (155017) Stainless steel front plate, standard, EN 13637 (193550) Stainless steel front plate RFID, surface-mounted EN 13637 (193551) TZ 320 UP control unit (129586) 19 20 GEZE EMERGENCY EXIT SYSTEMS | Terminal T 320 terminal Slave control unit for bi-directional escape routes with a TZ 320 or TZ 322 with integrated key switch ARE AS OF APP L I CAT I O N Terminal functions as additional interface for a TZ 320 to trigger an indirect release of a bi-directional emergency exit Realisation of a bi-directional emergency exit Realisation of an escape balcony PR OD U CT F E AT U R ES Flat impact cover enables fast and safe activation of the illuminated emergency push button in panic situations Coloured connectors facilitate electrical connection Integrated key switch enables authorised passing through emergency exit Illuminated emergency exit sign improves visibility Terminal | GEZE EMERGENCY EXIT SYSTEMS TE R MIN AL FOR B I - D I R ECT I O N A L ESCA P E RO UTES - T 320 SER I ES Your escape route goes in both directions? No problem! Doors that are to secure the escape route in both directions are equipped with a TZ 320 on one side and a T 320 on the other. Thus, in case of danger, the door can be safely unlocked from both sides at any time via an emergency push button. The activation of the electric locking element can be controlled via the terminal as well as via the door control unit. This locking element keeps the doors locked and prevents unauthorised access. TEC HN ICAL DATA T 320 AP terminal T 320 UP control unit Acoustic signal 75 dB 75 dB Illuminated optional no Operating voltage 24 V DC 24 V DC Width 77 mm for installation in 55 mm grid Height 197 mm for installation in 55 mm grid Depth 88 mm in flush-mounted sockets 62 mm deep With ribbon cable yes yes Type of installation Surface-mounted Flush-mounted Emergency push button yes yes Visual display yes yes Sabotage contact yes yes IP rating IP30 IP30 Current consumption 100 mA 100 mA Temperature range -10 °C...+55 °C -10 °C...+55 °C Supply voltage 24 V DC 24 V DC Delayed emergency push button no no Supply voltage 230 V 230 V Delayed emergency push button no no Cylinder type Euro profile half cylinder - Conform to EN 13637 yes yes BI-D IR ECTION A L ESCA P E R O U T E – SYSTEM STRUCTURE GEZE BUS … 2 TS 5000 BMA … FTV 320 … ZuKo … TZ 320 SN T 320 … 230 V AC 50 HZ … = signal horn I … = alarm message I … = Toplock I … = key switch I … = panic lock I … = terminal / door control unit 21 22 GEZE EMERGENCY EXIT SYSTEMS | Terminal SYSTE M D ES C R IP T I O N Authorised passage in the 1st direction of escape Authorised passage through the secured door in the 1st direction of escape is by means of a key switch integrated in the door control unit. In addition, passage via external elements e.g. access control or a key switch is also possible. The door is released for authorised passage for a configurable amount of time (short-time release). Authorised passage in the 2nd direction of escape Authorised passage through the secured door in the 2nd direction of escape is by means of a key switch integrated in the terminal. In addition, passage via external elements e.g. access control or a key switch is also possible. The door is released for authorised passage for a configurable amount of time (short-time release). Time monitoring of the door If the door is not closed after the release time for authorised activation has expired, a pre-alarm is triggered to draw attention to the time limit being exceeded. If the pre-alarm time is also exceeded, a door alarm is triggered and has to be acknowledged by the key switch. The door is equipped with a door closer to ensure it closes automatically after passage. Passing the door in case of an emergency The door can be released at any time in case of an emergency via the emergency push button integrated on the door control unit and/or on the terminal. Visual and acoustic signal transmitters integrated in the door control unit and in the terminal signal unauthorised passing of the door. There is also the possibility of triggering external signal transmitters via an alarm contact or relaying a message to a building management system. O RDE R IN FOR MAT I O N Designation Version ID no. T 320 AP terminal, EN 13637 Consisting of: control unit with emergency push button, key switch with Euro profile half cylinder, non-illuminated emergency exit sign white aluminium green 193548 193547 T 320 UP control unit (No complete flush-mounted set available, assembled of individual components) 140999 Terminal | GEZE EMERGENCY EXIT SYSTEMS Products T 320 AP control unit (193547) T 320 AP control unit (193548) T 320 UP control unit (140999) 23 24 25 AC C ESS C O N T RO L A N D SA FE T Y Locking elements A hazardous situation can cause panic and represent a danger to life – which is why it’s even more important that electrically locked doors clear the escape route immediately. Locking elements such as the GEZE escape door locks, react immediately when they are released by authorised parties or someone presses the emergency push button. Other advantages: they save space, are easy to install and provide protection against manipulation and vandalism, due to clever devices. We are happy to help you choose the right locking elements for your emergency exit. 26 GEZE EMERGENCY EXIT SYSTEMS | Locking element FTV 320 Escape door lock for doors in rescue routes ARE AS OF APP L I CAT I O N Single and double leaf doors Installation in the frame or the door leaf ensures a tidy appearance Can be used for numerous other safety solutions that require a fail-safe principle PR OD U CT FE AT U R ES Unique cross latch mechanism guarantees secure locking Integrated feedback contact ensures reliable monitoring of the door Integrated sabotage monitoring secures the locking mechanism against manipulation Variety of face plates and accessories offers a solution for almost every door situation Locking element | GEZE EMERGENCY EXIT SYSTEMS TEC HN ICAL DATA FTV 320 Height … mm Width 15 mm Depth 38 mm Operating voltage 24 V DC Current consumption in locked state 100 mA Service temperature -20 °C...+60 °C Latch preload 3,000 N Break-open resistance 5,000 N Clearance … +/- … mm DIN direction universal Feedback contact yes Fail-safe yes Conform to EN 13637 yes PR OD U CT S CA LE D R AW I N G S … 40 … 2 20 25 … 186 200 186 186 93 200 R1 … 200 … 24 2) .5(x n5 11 14 … = ID 158906 FTV 320 escape door lock face plate 20 x 200 x … mm, round for solid leaf doors (wood) I … = ID 158908 FTV 320 escape door lock Face plate 24 x 200 x … mm, rectangular, for tubular-framed door I … = ID 158913 FTV 320 escape door lock face plate 25 x 200 x … mm, rectangular, alternative version FTÖ 331 27 28 GEZE EMERGENCY EXIT SYSTEMS | Locking element PRO D U CT F E ATU R ES Planning reliability and simple consulting One escape door lock for many applications. The types of installation DIN right / DIN left, horizontal / vertical, in door leaf or door frame make the FTV 320 extremely versatile. Exchange with products from other manufacturers is no problem. The comprehensive range of accessories complies with the standard dimensions. Time-saving and failsafe Additional components such as relay boards are not necessary. The double assignment of terminals is not required, nor is the setting of cable bridges between two terminals. Space-saving The small dimensions and omission of the latch lock previously required, use of the FTV 320 avoids unnecessary recesses in the door or frame. Leaving more room for fireproof insulation on fire protection doors. Cables can be routed past the housing of the escape door lock. Simple to install Locking device and face plate are delivered pre-mounted. Two fixing screws are all that is required for safe attachment. The strike plate on the opposite side is also installed using only two screws. There is no need for a latch lock to be installed. Protection against vandalism and manipulation Unlike conventional latch locks, the cross latches of the FTV 320 are blocked in the locked state, which prevents them from being manipulated using a cheque card. The mechanism and integrated control circuit board are protected against manipulation attempts and report any attempts to a higher-order level. FT V 320 ES CA PE D O O R LO CK – O R D E R I N FO R M ATI O N Designation DIN door stop FTV 320 escape door lock Face plate 20 x 200 x … mm, round for solid leaf doors (wood) left/right Version 158906 ID no. FTV 320 escape door lock Face plate 24 x 200 x … mm, round for solid leaf doors (steel) left/right 158909 FTV 320 escape door lock Face plate 22 x 220 x … mm, rectangular for tubular-framed doors left/right 158907 FTV 320 escape door lock Face plate 24 x 200 x … mm, rectangular for tubular-framed doors left/right 158908 FTV 320 escape door lock Face plate 28 x 200 x … mm, rectangular for tubular-framed doors left/right 158910 FTV 320 escape door lock Face plate 30 x 200 x … mm, rectangular for tubular-framed doors left/right 158911 FTV 320 escape door lock Angled face plate 30 x 48 x 220 x … mm, rectangular Alternative version FTÖ 331 left/right 158912 FTV 320 escape door lock Face plate 25 x 200 x … mm, rectangular Alternative version FTÖ 331 left/right 158913 FTV 320 escape door lock Face plate with lock latch guide 35 x 200 x … mm, rectangular Alternative version FTÖ 331 left/right 158914 Locking element | GEZE EMERGENCY EXIT SYSTEMS FT V 320 ES CA P E D O O R LO C K – O R D E R I N FO RM ATI O N Designation DIN door stop Version ID no. Strike plate 20 x 110 x 3, round for solid leaf doors (wood) left/right stainless steel 159059 Strike plate 20 x 140 x 3, round for solid leaf doors (wood) left/right stainless steel 159050 Lipped strike plate, can be shortened 20 x 140 x … mm (core dimensions), round for solid leaf doors (wood) left/right stainless steel 159056 Adjustable lipped strike plate, can be shortened 20 x 140 x … mm (core dimensions), round for solid leaf doors left/right stainless steel 159063 Strike plate 24 x 110 x … mm, round for solid leaf doors left/right stainless steel 159061 Strike plate 24 x 140 x … mm, round for solid leaf doors (steel) left/right stainless steel 159053 Lipped strike plate, can be shortened 24 x 140 x … mm (core dimensions), round for solid leaf doors (steel) left/right stainless steel 159058 Adjustable lipped strike plate, can be shortened 24 x 140 x … mm (core dimensions), round for solid leaf doors left/right stainless steel 159064 Strike plate 20 x 110 x 3, rectangular for tubular-framed doors left/right stainless steel 163768 Strike plate 22 x 220 x … mm, rectangular for tubular-framed doors left/right stainless steel 159051 Strike plate 24 x 110 x 3, rectangular for tubular-framed doors left/right stainless steel 163769 Strike plate 24 x 130 x … mm, rectangular for tubular-framed doors left/right stainless steel 159060 Strike plate 24 x 140 x … mm (core dimensions), rectangular for tubular-framed doors left/right stainless steel 159052 Lipped strike plate, can be shortened 24 x 140 x … mm (core dimensions), rectangular for tubular-framed doors left/right stainless steel 159057 Adjustable lipped strike plate, can be shortened 24 x 140 x … mm (core dimensions), rectangular for tubular-framed doors left/right stainless steel 159065 Strike plate 28 x 130 x … mm, rectangular for tubular-framed doors left/right stainless steel 159062 Strike plate 28 x 140 x … mm, rectangular for tubular-framed doors left/right stainless steel 159054 Strike plate 30 x 140 x … mm, rectangular for tubular-framed doors left/right stainless steel 159055 Strike plate support 20 x 140 x … mm, rectangular left/right stainless steel 159066 Strike plate support 24 x 140 x … mm, rectangular left/right stainless steel 159067 Strike plate support 24 x 140 x … mm, rectangular left/right stainless steel 159068 Support FTV 320 24 x 200 x … mm, rectangular left/right stainless steel 159072 Support FTV 320 24 x 200 x … mm, rectangular left/right stainless steel 159071 Strike plate support 28 x 140 x … mm, rectangular left/right stainless steel 159069 Strike plate support 28 x 140 x … mm, rectangular left/right stainless steel 159070 29 30 GEZE EMERGENCY EXIT SYSTEMS | Locking element MA 500 holding magnet For magnetic locking of emergency exits in accordance with the fail-safe principle ARE AS OF APP L I CAT I O N Doors along escape and rescue routes Emergency exits PR OD U CT FE AT U R ES Integrated monitoring controls the locking status Separate door contact enables door status message Different installation sets offer three different installation situations Locking element | GEZE EMERGENCY EXIT SYSTEMS TEC HN ICAL DATA MA 500 Width 265 mm Height 66 mm Depth 41 mm Type of installation with corresponding installation set (hinge side, opposite hinge side or reveal) Service temperature -10 – 50 °C IP rating IP30 Operating voltage 24 V DC Current consumption 250 mA Feedback contact yes Fail-safe yes Conform to EN 13637 yes PR OD U CT S CA LE D R AW I N G IN STA LLATION SE T M A … 0 0, H I N G E SI D E 75 75 95 … 115 … 6 24 115 95 M6x20 … 33 … 33 mm … 2 115 16 26 26 17 33 146 24 23 … 8 37 24 26 … RWS M6x20 … 9 10 115 270 330 … = drilling template hinge side I … = door edge lock side I … = door DIN right I … = door DIN left I … = magnet with counterplate I … = mounting plate I … = lock washer I … = adjusting path I … = installation bracket I 10 = mounting bracket 31 GEZE EMERGENCY EXIT SYSTEMS | Locking element INSTA LLATION S E T M A … 0 0, O P P O SI T E H I NG E SI DE 10 16 115 115 20 RWS 17 26 … 154 … 2 … 24 … 17 26 … M6x20 26 71 … 146 57 33 33 M6x20 … 26 … 33 mm 20 … 20 270 75 20 20 30 … 7 … = drilling template opposite hinge side I … = frame lock side I … = door DIN right I … = door DIN left I … = magnet with counterplate I … = retaining plate I … = lock washer I … = adjusting path I … = installation bracket I 10 = mounting bracket INSTA LLATION S E T M A … 0 0, M O U N T I N G W I THI N R EVEAL 270 … 33 … 3 … 6 72 … 7 155 … 20 20 … 4 … 26 … 30 29 20 20 … 10 26 … 3 26 M6x20 11 29 33 29 26 17 RWS M6x20 … 20 115 26 115 75 32 … 6 30 20 20 155 20 20 … = drilling template mounting within reveal I … = reveal lock side I … = door DIN right I … = door DIN left I … = magnet with counterplate I … = retaining plate on the door I … = retaining plate I … = lock washer I … = lintel I 10 = mounting bracket I 11 = mounting bracket on the reveal Locking element | GEZE EMERGENCY EXIT SYSTEMS O R D E R IN FORM AT I O N Designation Version ID no. MA 500 holding magnet With counterplate silver-coloured 024740 Installation set MA 500, hinge side silver-coloured 024731 Installation set MA 500, opposite hinge side silver-coloured 024732 Installation set MA 500, mounting within reveal silver-coloured 025727 Surface-mounted magnetic contact Sensing distance 21 mm white 200386 Reed contact set white 106133 33 34 35 AC C ESS C O N T RO L A N D SA FE T Y System solutions We offer you complete solutions. From the initial consultation, the products and their installation through to the service following commissioning. Everything is tailored to your specific demands and needs. Our industry experts fully understand your concerns and will put together an individually tailored solution package. 36 GEZE EMERGENCY EXIT SYSTEMS | System solutions Emergency exit protection NURSE RY S C HOO L S O LU T I O N – F LE X I B LE AN D SAFE EN TRAN CE AN D EX I T CO N TR O L FO R N U R S E RY S CH O O LS With this emergency exit protection system for doors in nursery schools, the emergency exit is always locked and thus reliably protected against unauthorised passage. Unauthorised use of the emergency exit door by children can thus best be prevented by an approved system. The special feature of this system is the push button on the inside, which is positioned at a height of … m, inaccessible for children. In addition, the outside push button can be enabled or disabled via a switch for the parents during the arrival and pick-up periods. The activation of the emergency push-button – at a level children can reach – immediately releases the door and is signalled by both visual and acoustic alarms. This solution is also suitable for existing doors which are already fitted with an electric strike and a knob or pull handle on the outside. … 3 … 5 … 7 … 8 … 1 = panic lock with transmission function “E” on site I … = TS 4000/TS 5000 door closer I … = push button at … m height I … = switch to activate or deactivate the exterior push button I … = TZ 320 SN door control unit, surface-mounted/flush-mounted I … = FTV 320 escape door lock I … = A5000--B electric strike I … = key switch I … = push button outside System solutions | GEZE EMERGENCY EXIT SYSTEMS SYSTEM COMPONENTS TZ 320 SN door control unit, surface-mounted/flush-mounted ● FTV 320 escape door lock ● A5000--B electric strike ● RP 220 relay board ● Push button at … m height ● Push button outside ● Switch to enable or disable the outside push button ● TS 4000/TS 5000 door closer ● Panic lock with transmission function "E" on site ● OPTIONAL COMPONENTS Swing door drive as an alternative to the door closer for automatic door operation Holding magnet with installation set and door contact instead of escape door lock Flashlight Signal horn Uninterruptible power supply (UPS) Timer instead of the switch ● = yes SYSTE M D ES CR I P T I O N Passage by nursery school personnel Personnel triggers a short-time release on the door control unit by activating the outside key switch. The door can then be passed using the key on the panic lock. Pick up and drop off times The outside push button can be enabled or disabled via a switch in the office or on the door. This means that parents can trigger a short-time release when they are bringing or collecting their children, and open the door from the outside. Parents can leave the nursery school again by opening the door using the push button mounted at a height of … m. The installation height of … m means the push button is out of children's reach. Time monitoring of the door If the door is not closed after the release time has expired, a pre-alarm is triggered. This is to draw attention to the fact that the time has been exceeded. If the pre-alarm time is also exceeded, a door alarm is triggered and has to be acknowledged by the key switch. The door is equipped with a door closer to ensure it closes automatically after passage. Passing of the door in case of an emergency The door can be released at any time in an emergency by pressing the integrated emergency push button on the door control unit which is usually installed at a height of 850 mm and is thus also accessible for children. Visual and acoustic signal transmitters integrated in the door control unit signal passing of the door. There is also the possibility of triggering external signal transmitters via an alarm contact or relaying a message to a building management system. Burglary protection To lock the door in accordance with insurance requirements, nursery school staff must lock it manually using the panic lock. 37 38 GEZE EMERGENCY EXIT SYSTEMS | System solutions Emergency exit protection BI- D IR ECTION A L E M E R G E N CY E X I T P R OT ECTI O N FO R DO O R S W I TH EM ER G EN CY EX I T FUN CT ION IN BOTH D IR ECTIO N S. In the case of doors that serve as an escape route in both directions, a special system solution is necessary in order for them to make passage possible in both directions in emergency situations. With the GEZE system solution, doors along escape routes are generally held closed via an additional electrical locking element and thus reliably secured against unauthorised passage. Passage of the emergency exits is controlled by the TZ 320 door control unit. The T 320 terminal is fitted in the second direction of escape. In case of danger, the door can be safely unlocked from both sides at any time via an emergency push button. The door can be controlled and monitored via the T 320 terminal and via the TZ 320 door control unit. … 3 … 4 … = TS 4000/TS 5000 door closer I … = TZ 320 SN door control unit, surface-/flush-mounted I … = FTV 320 escape door lock I … = T 320 terminal surface- or flush-mounted System solutions | GEZE EMERGENCY EXIT SYSTEMS SYSTEM COMPONENTS TZ 320 SN door control unit, surface-mounted/flush-mounted ● T 320 terminal surface- or flush-mounted ● FTV 320 escape door lock ● TS 4000/TS 5000 door closer ● OPTIONAL COMPONENTS Holding magnet with installation set and door contact instead of escape door lock Flashlight Signal horn Uninterruptible power supply (UPS) Access control Connection to BACnet IP via myGEZE Control ● = yes SYSTE M D ES CR I P T I O N Authorised passage in the 1st direction of escape Authorised passage through the secured door in the 1st direction of escape is by means of a key switch integrated in the door control unit. In addition, passage via external elements e.g. access control or a key switch is also possible. The door is released for authorised passage for a configurable amount of time (short-time release). Authorised passage in the 2nd direction of escape Authorised passage through the secured door in the 2nd direction of escape is by means of a key switch integrated in the terminal. In addition, passage via external elements e.g. access control or a key switch is also possible. The door is released for authorised passage for a configurable amount of time (short-time release). Time monitoring of the door If the door is not closed after the release time has expired, a pre-alarm is triggered. This is to draw attention to the fact that the time has been exceeded. If the pre-alarm time is also exceeded, a door alarm is triggered and has to be acknowledged by the key switch. The door is equipped with a door closer to ensure it closes automatically after passage. Passing the door in case of an emergency The door can be released at any time in case of an emergency via the emergency push button integrated on the door control unit and/or on the terminal. Visual and acoustic signal transmitters integrated in the door control unit and in the terminal signal unauthorised passing of the door. There is also the possibility of triggering external signal transmitters via an alarm contact or relaying a message to a building management system. 39 40 GEZE EMERGENCY EXIT SYSTEMS | System solutions Central control FOR D OOR S IN IN T E R LO CK I N G D O O R SYSTEM S This system allows interlocking door systems (active or passive) in the course of escape routes, e.g. in operating wings, laboratory and quarantine wards, to be achieved. This is the case when several doors are released in succession and may only be passed once the respective previous door has been closed again. The doors in one group mutually lock each other. A door control unit can be assigned to several groups at the same time. The interlocking door system relations can be changed at any time through simple parameter setting. A maximum of 10 interlocking door groups with altogether up to 63 door control units each are possible per bus system. For both types of interlocking door system, immediate access can be gained by activating the emergency push button. The interlocking door system function can be switched on and off by means of key switches. … 3 … 2 … 2 … = TS 4000 / TS 5000 door closer I … = TZ 320 SN door control unit, surface-/flush-mounted, reader integrated I … = traffic light display red / green I … = FTV 320 escape door lock System solutions | GEZE EMERGENCY EXIT SYSTEMS SYSTEM COMPONENTS TZ 320 door control unit ● FTV 320 escape door lock ● Traffic light display red/green ● Push button ● Power supply ● TS 4000 / TS 5000 door closer ● OPTIONAL COMPONENTS Holding magnet with installation set and door contact instead of escape door lock Red indicator lamp instead of the traffic light display IQ lock EL motor lock IQ lock EM lever lock IQ lock C contact lock Slimdrive EMD / Powerturn swing door drive Timer (ZSU) Flashlight Signal horn Uninterruptible power supply (UPS) ● = yes SYSTE M D ES CR I P T I O N Active interlocking door system In the closed state, all the doors configured as part of an active interlocking door group are locked. If one of these doors is released short-term via respective activation devices, it transmits a signal to all the other doors in the group at the same time and prevents short-time unlocking. Passive interlocking door system In contrast to the active interlocking door system, all the doors configured as part of a passive interlocking door system are not generally locked when in a closed state. If one of these doors is opened, it transmits a signal to all other doors and locks these. Mixed interlocking door system (active and passive) Both interlocking door system types can be combined in one interlocking door group. Continued locking of interlocking door system doors for pressure compensation or air purification, e.g. in clean rooms A time can be set for the interlocking door system to remain locked after it has been passed through (locking all the doors of an interlocking door group). Different times can be set at all the door control units of an interlocking door system. It is possible, for example, to keep the door locked for … s following passage from a clean room to a grey room, and for 15 s following passage in the opposite direction (grey room > clean room), since more time is required to clean the air in this case. Authorised passage from the non-secured area into the interlocking door system Authorised passage from the non-secured area is by means of electric access control using a card reader or the integrated key switch of the door control unit. The door is released for authorised passage for a configurable amount of time (shorttime release). 41 42 GEZE EMERGENCY EXIT SYSTEMS | System solutions SYSTE M D ES C R IP T I O N – C O N T I N UAT I O N Authorised passage out of the interlocking door system In the interlocking door system, the doors are released via a push button without special authorisation. If a higher safety standard is required, an electric access control or mechanical key switch must be used here as well. Authorised passage out of the secured area into the interlocking door system In the secured area, the door is released via a push button without special authorisation. If a higher safety standard is required, an electric access control or mechanical key switch must be used here as well. Opening multiple doors in an interlocking door system for transportation purposes The "permanent unlocking" function on the door control units is used to disable the interlocking door system function. Several doors in one interlocking door group can then be opened at the same time. If deactivation of the interlocking door system is not possible for safety reasons, the "permanent unlocking" function can be suppressed on the door control units. Visual display of the interlocking door system status A locked interlocking door system is indicated by the integrated LEDs on the door control unit flashing red. In addition, the traffic light display is green when the interlocking door system can be entered and red when it is locked. As an option, the system can display only a red signal; this indicates that the interlocking door system is occupied. If no visual signal is displayed, the door can be passed. Time monitoring of the door If the door is not closed after the release time has expired, a pre-alarm is triggered. This is to draw attention to the fact that the time has been exceeded. If the pre-alarm time is also exceeded, a door alarm is triggered and has to be acknowledged by the key switch. The door is equipped with a door closer to ensure it closes automatically after passage. Automated interlocking door systems In the context of interlocking door system control it is also possible to activate swing door drives via the door control unit and thus to open and close doors in defined building sections. If a door is locked by the door control unit (basic state of active interlocking door system), the door drive is in the so-called night mode. If the short-time release is triggered, the drive is automatically activated and the door opens. After the hold-open time set on the drive has passed, the door closes and the door control unit locks the door. If a door is in an unlocked state (basic state of passive interlocking door system), the door drive is switched to automatic mode. The activation devices connected to the drive are active as long as the door is unlocked. If the door control unit locks, all the activation devices belonging to the automation are without function. Passing of the door in case of an emergency The door can be released in case of an emergency at any time via the integrated emergency push button. Visual and acoustic signal transmitters integrated in the door control unit signal unauthorised passing of the door. There is also the possibility of triggering external signal transmitters via an alarm contact or relaying a message to a building management system. Integrating doors without escape route function Other types of doors such as sliding doors, industrial doors etc. can be integrated in a simple interlocking door system relation by means of the door control units. In this case, the door control unit serves only as an interlocking door system control which interrupts or releases the activation devices of the other doors. Its standardisation means that this solution is more straightforward than an interlocking door system control via a programmable logic controller (PLC) which generally requires separate programming and a cable plan and wiring diagram. System solutions | GEZE EMERGENCY EXIT SYSTEMS 43 44 45 AC C ESS C ON T RO L A N D SA FE T Y Individual components and accessories 46 GEZE EMERGENCY EXIT SYSTEMS | Individual components Key switches SCT 320 U P K E Y SW I TC H Areas of application – Authorised control of operating statuses on various GEZE products – Approved for use with GEZE emergency exit system door control units – Designed for Euro profile half cylinder 30/10 – Dry internal applications – Flush-mounted installation makes almost flush integration possible with a low installation height Product features – Two-sided switching operation, with Euro profile half cylinder and three keys – With ribbon cable for convenient connection to the emergency exit system flush-mounted door control unit – With integrated sabotage contact – Designed for installation in 55-type flush-mounted ranges TECHN ICAL DATA SCT 320 UP IP rating IP20 Type of installation Flush-mounted Material Plastic Switching voltage 24 V DC Switching current 1A SCT … 20 U P K E Y SW I TC H Areas of application – Authorised control of operating statuses on various GEZE products – Approved for use with GEZE emergency exit system door control units – Designed for Euro profile half cylinder 30/10 – Dry internal applications – Flush-mounted installation makes almost flush integration possible with a low installation height Product features – With single frame – Two-sided switching operation, with Euro profile half cylinder and three keys TECHN ICAL DATA SCT 220 UP IP rating IP20 Type of installation Flush-mounted Material Stainless steel or plastic Switching current 10 A Switching voltage 250 V AC Individual components | GEZE EMERGENCY EXIT SYSTEMS SCT … 2 … K E Y S W I TCH W I T H LE D Areas of application – Authorised control of operating statuses on various GEZE products – Approved for use with GEZE emergency exit system door control units – Designed for Euro profile half cylinder 30/10 – Outer areas due to high IP rating Product features – With integrated LED display for status feedback – Right LED red/green and left LED yellow – High-quality aluminium front plate – Two-sided switching operation, with Euro profile half cylinder and three keys – Sabotage-proof design, can only be opened with key TEC HN ICAL DATA SCT 222 with LED IP rating IP54 Type of installation Surface or flush-mounted Material Aluminium Switching current 5A Switching voltage 230 V AC KE Y S WITC H STAY- P U T W I T H O U T E U R O PR O FI LE HALF CYLI N DER Areas of application – For authorised activation of automatic doors – For authorised changing of the mode of operation on automatic doors – Internal application, some outer areas Product features – IP rating IP54 – Stay-put on both sides – Cover can only be removed with the key – Light alloy housing TEC HN ICAL DATA SCT stainless steel IP rating IP54 Type of installation Flush-mounted installation Material Light alloy housing Switching current 5A Switching voltage 230 V AC 47 48 GEZE EMERGENCY EXIT SYSTEMS | Individual components EURO -P R OF ILE H A LF CY L I N D E R … 0 M M … 0 /1 … Areas of application – Lock cylinder for activation of one or both sides of the door – For key switches, manual locking devices, hook bolt locks Product features – Euro profile half cylinder 30/10 ORD E R IN FOR MAT I O N Designation Type of installation Version ID no. Flush-mounted SCT 320 key switch Two-sided switching operation, with Euro profile half cylinder and three keys Flush-mounted Flush-mounted Frame available separately. alpine white pure white matt anthracite 131984 130370 132278 SCT 221 key switch Single-sided switching operation, without Euro profile half cylinder silver-coloured silver-coloured 054240 054532 SCT 220 key switch, Jung LS 990 Flush-mounted Two-sided switching operation, with Euro profile half cylinder and three keys stainless steel 094170 SCT 220 key switch, GIRA E2 Flush-mounted Two-sided switching operation, with Euro profile half cylinder and three keys pure white matt 094012 SCT 222 key switch with LEDs Surface-mounted Two-sided switching operation, with Euro profile half cylinder and three keys Flush-mounted silver-coloured silver-coloured 100065 100064 Key switch stay-put without Euro profile half cylinder silver-coloured 111357 Euro-profile half cylinder 40 mm 30/10 Flush-mounted Surface-mounted Flush-mounted 090176 Individual components | GEZE EMERGENCY EXIT SYSTEMS Emergency push buttons NOT 320 E ME R G E N CY P U S H B U T TO N Areas of application – Mains voltage can be switched off in the case of an emergency and during maintenance work – Indirect activation of GEZE emergency exit system door control units – Opening of automatic doors in case of an emergency Product features – LED lighting for better visibility, even in the dark – Re-usable cover that protects against dust and dirt – Contact system consists of one normally closed contact and one normally opened contact – Flat impact cover enables fast and safe activation of the illuminated emergency push button in panic situations TEC HN ICAL DATA NOT 320 emergency push button IP rating IP20 Type of installation Surface or flush-mounted Material of impact cover Transparent plastic Operating voltage 24 V DC Current consumption 30 mA Number of cores … Number of relays … Visual operating state display yes Sabotage contact yes Contact rating 30 V / … A Temperature range -10 °C ... +50 °C 49 50 GEZE EMERGENCY EXIT SYSTEMS | Individual components NOT … 20 A P E ME R G E N CY P U S H B U T TO N Areas of application – Mains voltage can be switched off in the case of an emergency and during maintenance work – Indirect activation of GEZE emergency exit system door control units – Opening of automatic doors in case of an emergency – Surface-mounted installation for simple installation without a lot of installation effort – Outer areas due to high IP rating Product features – LED lighting for better visibility, even in the dark – Contact system consists of one normally closed contact and one normally opened contact – A second normally closed contact is available as an accessory – Robust plastic housing protects the emergency push button reliably from mechanical effects TECHN ICAL DATA NOT 220 AP emergency push button Dimensions 94 x 94 x 122 mm IP rating IP65 Type of installation surface-mounted Operating voltage 24 V DC Current consumption 15 mA Number of outputs … Temperature range -25 °C ... +70 °C NOT … 20 U P E ME RG E N CY P U S H B U T TO N Areas of application – Mains voltage can be switched off in case of an emergency – Mains voltage can be switched off in case of maintenance work – Indirect activation of GEZE emergency exit system door control units – Opening of automatic doors in case of an emergency – Flush-mounted installation makes almost flush integration possible with a low installation height Product features – LED lighting for better visibility – Contact system consists of one normally closed contact and one normally opened contact – A second normally closed contact is available as an accessory TECHN ICAL DATA NOT 220 UP emergency push button IP rating … x … x 98 mm Type of installation IP20 Type of installation flush-mounted Operating voltage 24 V DC Current consumption 15 mA Number of outputs … Temperature range -25 °C ... +70 °C Individual components | GEZE EMERGENCY EXIT SYSTEMS OR D E R IN FORM AT I O N Designation Version ID no. NOT 320 UP emergency push button without frame surface-mounted 136571 NOT 320 AP emergency push button with surface mounted cap Jung AS 500 and … x frame flush-mounted 137967 NOT 220 AP emergency push button surface-mounted 210203 NOT 220 UP emergency push button flush-mounted 210204 51 52 GEZE EMERGENCY EXIT SYSTEMS | Individual components Emergency exit signs FWS 320 B E ME R G E N CY E X I T SI G N E N … 3 637 Areas of application – Doors along escape and rescue routes – Illumination of the emergency exit sign in an emergency exit system door control unit for better visibility Product features – Flat design for flush-mounted and surface-mounted installation – Energy-efficient LED technology – With ribbon cable for convenient connection to the emergency exit system door control unit – Designed for installation in 55-type flush-mounted ranges TECHN ICA L DATA FWS 320 B emergency exit sign EN 13637 Dimensions 55 x 10 x 55 mm Type of installation Flush-mounted installation Material Plastic Operating voltage 24 V DC Current consumption 10 mA EMER GE N CY P U S H B U T TO N N OT I C E SI G N EN … 3 637 Areas of application – Doors along escape and rescue routes Product features – Self-adhesive TECHN ICAL DATA Emergency push button notice sign EN 13637 Dimensions 94 x 94 mm Colour green (RAL 6032) ORD E R IN FOR MAT I O N Designation Version ID no. FWS 320 B emergency exit sign EN 13637 illuminated with ribbon cable for installation on TZ 320 / SCT 320 green 193554 Emergency push button notice sign EN 13637 self-adhesive, dimensions: 94 x 94 mm green 193993 Individual components | GEZE EMERGENCY EXIT SYSTEMS Power supply NT … A-2 … V U P P OW E R SU P P LY Areas of application – Flush-mounted installation of the power supply – For the supply of 24 V drives and control units Product features – Compact power supply TEC HN ICAL DATA NT … A-24 V UP power supply (151426) Dimensions (W x H x D) 54 x 54 x 32 mm Output voltage 24 V DC Output current (max.) … A POW E R S U P PLY … 4 V D C ( N T 1. … A-2 … V HS) Areas of application – For installation on top hat rails – For the supply of 24 V drives and control units Product features – Quick and easy installation – Powerful power supply with small dimensions TEC HN ICAL DATA NT … A-24 V HS (151425) Dimensions (W x H x D) 35 x 90 x 58 mm Output voltage 24 V DC Output current (max.) … A Division units … division units 53 54 GEZE EMERGENCY EXIT SYSTEMS | Individual components POW E R S U P PLY … 4 V D C ( N T … . … A-2 … V H S) Areas of application – For installation on top hat rails – For the supply of 24 V drives and control units Product features – Quick and easy installation – Powerful power supply with small dimensions T ECH N ICAL DATA NT … A-24 V HS (151424) Dimensions (W x H x D) 52 x 90 x 58 mm Output voltage 24 V DC Output current (max.) … A Division units … division units POWE R S U P PLY … 4 V D C ( N T 6. 25 A-2 … V HS) Areas of application – For installation on top hat rails – For the supply of 24 V drives and control units Product features – Quick and easy installation – Powerful power supply with small dimensions TECHN ICAL DATA NT … A-24 V HS (192113) Dimensions (W x H x D) 72 x 95 x … mm Output voltage 24 V DC Output current (max.) … A Division units … division units Individual components | GEZE EMERGENCY EXIT SYSTEMS ST E P-U PS U N I N T E R R U P T I B LE P OW E R SUPPLY Areas of application – For installation on top hat rails – Approved for use with GEZE emergency exit system door control units Product features – Lithium-ion technology ensures low battery maintenance and a long service life – Integrated battery module enables compact design and space-saving top hat rail – Battery module installed without tools for easy replacement – Automatic, cyclical battery quality testing guarantees reliable operation and promptly signals when a battery needs to be replaced – Deep discharge protection protects the battery against damage, even under high loads – Alarm status is displayed visually on the device and can be transmitted via contact – Charge status is displayed visually on the device and can be transmitted via contact – Battery status is displayed visually on the device and can be transmitted via contact – Adjustable buffer time allows for individual adjustment to fit any application TEC HN ICAL DATA Phoenix Contact UPS 24 V DC, 46 WH (193212) Dimensions (W x H x D) 108 x 90 x 71 mm Output voltage 24 V DC Output current (max.) 3A Division units … division units OR D E R IN FOR M AT I O N Designation Version ID no. NT … A-24 V UP power supply black 151426 NT 24- … A - 24 V DC power supply grey 078401 NT … A-24 V HS power supply black 151425 NT … A-24 V HS power supply black 151424 NT … A-24 V HS power supply grey 192113 STEP-UPS uninterruptible power supply grey 193212 55 56 GEZE EMERGENCY EXIT SYSTEMS | Individual components Indicator lamps and signal horns SLE … 20 U P IN D ICATO R L A M P, G R E E N Areas of application – Increases safety even in large rooms – Approved for use with GEZE emergency exit system door control units – Designed for installation in 55-type flush-mounted ranges Product features – Warning light for reinforcing an optical alarm signal TECHN ICAL DATA SLE 220 UP indicator lamp, green Reflector colour green Operating voltage 24 V DC Current consumption 18 mA Switch programme Jung AS 500, alpine white SLE … 20 U P IN D ICATO R L A M P, R E D Areas of application – Increases safety even in large rooms – Approved for use with GEZE emergency exit system door control units – Designed for installation in 55-type flush-mounted ranges Product features – Warning light for reinforcing an optical alarm signal TECHN ICAL DATA SLE 220 UP indicator lamp, red Reflector colour red Operating voltage 24 V DC Current consumption 18 mA Switch programme Jung AS 500, alpine white Individual components | GEZE EMERGENCY EXIT SYSTEMS SLE 220 IN D ICATO R L A M P SU R FACE- M O UN TED Areas of application – Increases safety even in large rooms – Approved for use with GEZE emergency exit system door control units Product features – Warning light for reinforcing an optical alarm signal – Surface-mounted installation for simple installation without a lot of installation effort TEC HN ICA L DATA SLE 220 indicator lamp surface-mounted Dimensions (W x H x D) 61 x 61 x 74 mm Reflector colour red Operating voltage 24 V DC Current consumption 85 mA / 24 V Switch programme Jung AS 500, alpine white IP rating IP20 FLAS HLIGHT Areas of application – Increases safety even in door situations that are poorly visible – Approved for use with GEZE emergency exit system door control units – In humid environments due to high IP rating Product features – Surface-mounted installation for simple installation without a lot of installation effort – Sturdy, maintenance-free and fail-safe design due to the reflector’s polycarbonate housing – Xenon tubes for high visibility performance TEC HN ICA L DATA Flashlight Dimensions (Ø x H) 93 x 72 mm Reflector colour red Flashing frequency … Hz, ± 20 % Operating voltage 20-30 VDC Current consumption 90 mA IP rating IP54 57 58 GEZE EMERGENCY EXIT SYSTEMS | Individual components SIGN AL HOR N Areas of application – Increases safety even in door situations that are poorly visible – Approved for use with GEZE emergency exit system door control units – In humid environments due to high IP rating – Surface-mounted installation for simple installation without a lot of installation effort Product features – Controllable volume to make every application situation possible – 26 settings for signal tone TECHN ICAL DATA Signal horn Dimensions (Ø x H) 111 x … mm Reflector colour red Signal sound 26 settings Volume adjustable between 74 and 94 dB Operating voltage 10-28 VDC Current consumption 16 mA IP rating IP54 MU LTIFU N CTION A L SI R E N Areas of application – Increases safety even in large rooms – Approved for use with GEZE emergency exit system door control units – In humid environments due to high IP rating – Designed for installation in 55-type flush-mounted ranges – Can be mounted in flush-mounted sockets … mm deep Product features – Controllable volume to make every application situation possible – 28 settings for signal tone TECHN ICAL DATA Multifunctional siren Volume 20 - 107 dB/A (in … m) Signal sound Choice of 28 tones Operating voltage 10 - 28 V DC Current consumption 10 mA IP rating IP54 Installation flush-mounted sockets … mm deep Switch programme Jung AS 500, alpine white O RDE R IN FOR MAT I O N Designation Version ID no. SLE 220 indicator lamp flush-mounted green red 115936 115934 SLE 220 indicator lamp surface-mounted red 020866 Flashlight red 199465 Signal horn white 199469 Multifunctional siren alpine white 199471 Individual components | GEZE EMERGENCY EXIT SYSTEMS Synchronising unit ST … 20 S E RV IC E T E R M I N A L Areas of application – Emergency exit system door control units – Motor locks – Building automation components – Automatic door drives – Automatic window drives Product features – IR interface for the wireless parameter setting of emergency exit system door control units – … AAA batteries for wireless operation – Wired parameter setting via RS 485 bus – Voltage supply via cable in the case of wired operation – Four-line display and slim user interface for simple operation TEC HN ICAL DATA ST 220 service terminal Dimensions 80 x 125 x 37 mm IP rating IP40 O R D E R IN FOR M AT I O N Designation ID no. 087261 ST 220 service terminal Parameter setting and diagnosis for TZ 320, automatic sliding and swing door systems from DCU software … and IQ windowdrive, battery operation with … x AA cells (not supplied by GEZE), plain text display on illuminated display, membrane keyboard for operation 59 60 61 AC C ESS C O N T RO L A N D SA FE T Y Operating elements Locked safely – and yet open in emergencies. Finally, emergency exit electric strikes must also be operated reliably, which is the purpose of the range of operating elements. If your building possesses several emergency exits, you can control and manage them. Another intelligent product is the GEZE Cockpit, our building automation system, which networks door and window technology – and increases safety even more. 62 GEZE EMERGENCY EXIT SYSTEMS | Operating elements myGEZE Control connectivity platform Controller system as maximum system expansion with GEZE CAN bus, I/O technology and KNX to connect all GEZE products and third-party products. SYSTE M C O N S I ST I N G O F Basic device 10x 8-channel digital input terminal Potential distribution terminals 24 V DC Power supply terminal 10x output terminals 2-channel-relay 10x output terminals 4-channel-relay 5x CAN-master terminal + CAN-connector E-bus coupler 2x terminal KNX/EIB Bus end terminal AR E AS OF A P P L I CAT I O N BACnet IP integration in building management systems Networking of GEZE products that can be connected with CAN bus technology Networking of non BUS capable components via digital input and output terminals Networking of KNX capable GEZE window drives in the building management system Products suitable for emergency exit systems: TZ 320, TZ 321 and TZ 322 Products suitable for automatic door drives: Slimdrive, Powerturn, TSA 325 NT and Revo.PRIME Products suitable for smoke and heat extraction systems: MBZ 300 in different versions Products suitable for window systems: Slimchain, Powerchain, F 1200+ and locking systems For products with I/O technology like GEZE hold-open systems and third-party products Operating elements | GEZE EMERGENCY EXIT SYSTEMS P R OD U CT F E AT U R ES System is also available without CAN master terminals and digital input and output terminals Maximum system expansion for one control unit, which allows for the connection of up to 200 product systems from the entire product portfolio Comprehensive, project-specific configuration according to user specifications possible (system designation, comment texts, status texts) Time function and grouped switching commands configurable via scene applications BACnet alarm concept integrated, can be adjusted to customer-specific requirements PRODUCT FEATURES myGEZE Control with GEZE CAN bus, I/O technology and KNX Controller system to connect GEZE CAN products and non bus-capable components as well as KNX/EIB components myGEZE Control with GEZE CAN bus and I/O technology k Controller system to connect GEZE CAN products and non bus-capable components to the GEZE building system myGEZE Control with GEZE CAN bus, Control unit system for smaller applications to connect the GEZE CAN products over multiple bus lines BASIC DEVICE myGEZE Control basic device Powerful embedded PC for top hat rail mounting with integrated BACnet communication TERMINALS myGEZE Control CAN master terminal Master in terminal system for integration of the GEZE CAN devices over multiple bus lines myGEZE Control 8-channel digital input terminal Digital input terminal with eight inputs to detect binary control signals from the process level myGEZE Control output terminal 2-channel relay Digital output terminal with two potential-free relay outputs and one change-over contact for each myGEZE Control output terminal 4-channel relay Digital output terminal with four potential-free relay outputs and one single contact for each myGEZE Control potential distribution terminal 24 V DC Potential distribution provides 16 terminal points with a 24 V DC potential myGEZE Control potential distribution terminal … V DC Potential distribution provides 16 terminal points with a … V DC potential myGEZE Control power supply terminal To refresh the E-bus via data exchange between the basic controller and terminals myGEZE Control terminal KNX/EIB EIB/KNX bus terminal for connection to the KNX/EIB network myGEZE Control bus end terminal For data exchange between the bus coupler and bus terminal COUPLERS myGEZE Control E-bus coupler Connects terminal system and serves to install detached coupling stations (distribution box) CONNECTORS myGEZE Control CAN connector Connector in the housing for use with the myGEZE Control CAN master terminal COVERS myGEZE Control bus end cover To cover the E-bus contacts 63 64 GEZE EMERGENCY EXIT SYSTEMS | Operating elements myGEZE Visu Building management software for visualisation, operation, control and monitoring of connected GEZE product systems AR E AS OF A P P L I CAT I O N Operation of a building management system for door, window and safety technology of GEZE product systems and competitors Visualisation, operation and monitoring of connected GEZE products Use of standardised workflows to release incidents Alarm concepts for forwarding incidents in modern facility management systems PR OD U CT F E AT U R ES Visualisation system with modular and flexible authorisation concept Visualisation, operation, and monitoring of connected GEZE product systems Location option for devices on a customer-specific building plan Pre-defined, adaptable alarm concept for multi-stage processing of alarms, faults and messages Application for using e-mail notification service Multi-station capable operating system Activation of further functions via license model Simple and intuitive interface set-up and configuration Optimised for connection to myGEZE Control systems Parallel operation with any building management system possible Operating elements | GEZE EMERGENCY EXIT SYSTEMS Accessories IO 420 E X TE N S I O N M O D U LE Area of application – Module to expand the digital inputs and outputs on the TZ 320 Product features – Plastic top-hat rail housing for installation in the control cabinet or suspended ceiling – Four integrated relays, each with a potential-free changeover contact for carrying out switching functions – Four integrated inputs for the release of switching functions and/or the placement of messages – Connection between the interface modules via RS 485 interface in line topology TEC HN ICA L DATA IO 420 extension module Dimensions 107 x 111 x 59 mm Service temperature -20 °C...+80 °C Operating voltage 24 V DC LEDs … (red), … (yellow), … (red), … (green), … (green), … (yellow), in (green), out (red) Interfaces GEZE bus … inputs … outputs DIP switch GEZE bus terminating resistor 120 Ohm Micro SD card FAT16/32 file format for setting parameters and changing settings via PC Reset button to reset factory settings 65 66 GEZE EMERGENCY EXIT SYSTEMS | Operating elements BUS R E P E ATE R Areas of application – Networked GEZE emergency exit systems Product features – For extending the bus length by a further 900 m – For installation on standard carrier rails – Several repeaters and carrier rail connectors are needed for implementing star and tree structures TECHN ICA L DATA BUS repeater Dimensions … x 66 x … mm IP rating IP20 Type of installation Top hat rail mounting Supply voltage 10 - 32 V DC Current consumption 80 mA (at 24 V DC) O RDE R IN FOR MAT I O N Designation ID no. CAN interface galvanically isolated CAN extension module for automatic sliding door, revolving door and swing door drives 119952 BUS repeater 142499 Contents | GEZE EMERGENCY EXIT SYSTEMS 67 We are GEZE. For liveable buildings GEZE stands for innovation, high quality and comprehensive support of building technologies. From the initial idea, planning and operational implementation with standard products to customised system solutions and individual service and maintenance plans. We offer an extensive product range of door, window and safety technology products and are a major driving force behind the digital networking of building automation. GEZE GmbH Reinhold-Vöster-Strasse 21 – 29 71229 Leonberg Germany Phone: +49 7152 203 … Fax: +49 7152 203 310 E-Mail: info.de@geze.com www.geze.com 2024_09 ID no. 132408 EN Subject to change without notice
Emergency unlocking lever
IQ lock Emergency Power
GEZE Service emergency exit systems
(DOCUMENT | 36 KB)
IQ lock Emergency power buffer
Emergency push button NOT 320
Emergency exit sign FWS back
Emergency push button NOT 320 with emergency exit sign GIRA Profil 55, ALU