Search filter
6 results found
Branch offices and directions
… map. GEZE South Africa (Pty) Ltd. branch offices in South Africa HEAD OFFICE GEZE South Africa (Pty) Ltd. Corporate Park South, Building
… Mapping of even complex smoke and heat extraction systems with PC software — Configurable ex-works as an individual solution — Can be used as a central control unit or in the form COMPACT —P lastic housing (THZ) or metal housing (THZ Comfort) with integrated SHEV and ventilation Power lock: Secure locking mechanism buttons — L ocking drive for large windows —S uitable for use in frame and leaf installation —F lexible retrofitting with the chain and spindle drives —C an be used with Slimchain, Powerchain and the E 250 NT —C ompact staircase control panels with an output power of
… mapping of even complex RWA systems with PC software • can be configured ex works as an individual solution • can be used as a central control unit or in the form of multiple networked control units • compact chain drive for unobtrusive façade design • suitable for natural ventilation, RWA and SHEVs • different stroke versions of 300 mm, 500 mm and 800 mm • individual adjustment of drive stroke and speeds • easy synchronisation of up to four drives without an external control unit • strong chain drive for heavy window façades, roof windows and skylights • suitable for natural ventilation, RWA and SHEVs • achieves high opening speeds in RWA situations • different stroke versions of 600 mm, 800 mm and 1,200 mm • individual adjustment of drive stroke and speeds • easy synchronisation of up to four drives without an external control unit • Locking drive for large windows • Can be used for frame and leaf installation • Flexible retro-fitting with the new chain and spindle drives • Can be used with Slimchain, Powerchain and the • E 250 NT spindle drive in SHEVs • Standard central locks possible • Simple commissioning and automatic sequence control 15 GEZE – System intergation made easy! Intelligent building automation in the BACnet world via the IO 420 interface module Building-specific solution for modern building management system Project: Construction of a new office complex Focus: • building automation system with intelligent control • interoperability between automated trades Requirement: • • • • • monitoring and control of escape doors via a building management system changing of modes of operation and status monitoring of automatic door systems activation of hold-open systems controlling the flow of people into buildings – as needed (e.g. for events) status monitoring of the RWA system and activation of the multifunctional RWA fresh air supply door GEZE solution: • connection of the installed GEZE products (TZ 320 door control unit, swing door drives, revolving doors, motor locks, hold-open systems) via the IO 420 interface module on BACnet MS/TP • integration of third-party products such as high-speed doors 16 17 GEZE – System intergation made easy! Building control Elsner WS 1000 Style ECturn Inside KNX display Corlo Touch mit WLAN TOF/Spot time of flight measurement (AIR) GEZE IQ box KNX 1. Automated entrance door with improved burglar resistance 2. Automated ventilation window Slimchain GEZE SecuLogic GCER 100 18 19 GEZE – System intergation made easy! GEZE IQ box KNX: direct dialogue between windows and components A natural, energy-efficient supply of fresh air whenever needed – entirely on demand and under control at all times: the new GEZE IQ box KNX interface module allows GEZE IQ windowdrives to be directly incorporated in KNX building systems. Thus enabling a dialogue with other KNX-enabled components, such as push buttons and sensors. In contrast to simple switch contacts, the IQ box KNX uses the intelligence of the window drives and after performing a 'command' reports the mode of a window to the KNX building system or building management system. More detailed window information is also made available via the module, such as the precise opening width. At a glance: • precise positional activation of GEZE IQ windowdrives • safe integration in the KNX world • easy and time-saving installation and commissioning • scalable system – depending on the needs • reliable status report from every automated window • more efficient window monitoring 20 21 GEZE – System intergation made easy! 22 1. Automated entrance door with improved burglar resistance 2. Automated ventilation window Outstanding protection against burglary, controlled access and comfortable use: multifunctional door systems are also becoming increasingly important in the entrance areas of private houses or smaller commercial buildings. GEZE offers solutions that are fully tailored to the individual need. For example with the ECturn Inside automatic swing door drive, a multi-point locking system and the new SecuLogic GCER 100 stand-alone access control system. This can be combined with all motor locks and multi-point locking systems on front doors. It also fits perfectly into the world of GEZE system products and controls swing and sliding door drives, electric strikes, panic locks and emergency exit control. The GEZE solutions for ventilation and indoor climate control complete the comprehensive range of drive systems for daily ventilation, as well as the GEZE RWA systems and can be optimally combined with these. Via a KNX interface of the indoor climate control, this control can be integrated into an overall KNX system, and existing KNX devices can be used for its activation. GEZE solutions offer building operators a variety of automation, comfort and safety functions. ECturn Inside: barrier-free doors GEZE SecuLogic GCER 100: keyless access control Slimchain: slim all-rounder TOF/Spot time of flight measurement (AIR): compact unit • compact automatic swing door drive • flexible integration in various door leaves or door frames • operation in low-energy and automatic mode • for door leaf widths of up to 1,100 mm or leaf weights of up to 125 kg • optional rechargeable battery for continued operation in the event of a power failure • additional sensors can be connected • access control system for smaller buildings and up to 100 persons • use of ID cards, key rings (“tags”) and all standard car keys possible • managed using a master card • encrypted data transmission for high data security • straightforward commissioning • inside and outside use • compact chain drive for unobtrusive façade design • suitable for natural ventilation, RWA and SHEVs • different stroke versions of 300 mm, 500 mm and 800 mm • individual adjustment of drive stroke and speeds • easy synchronisation of up to four drives without an external control unit • • • • • • • • self-monitoring compact sensor precise light beam for protection hides certain detection areas suitable for installing in façade, wall or ceiling elements. inside and outside use (protection rating IP65) dimensions of detection field approx. 40 x 40 mm at a distance of
… map several control units connected via CAN-bus. (This function only becomes effective when the "Networked control units" program version is used.) Delete selection Delete all Deletes the module selected in the list Deletes all the modules from the list Load into App Def. Cfg. Loads the list as system set-up into the configuration program. When configuration has been completed it can be saved (*.EMB) in order to be exported to an actually existing control unit locally at a later date. The configuration file of an actually existing system can also be loaded into an identical, emulated system. The configuration can only be loaded to an identical control unit (same module sequence). The set-up must be known. Tip: Always save the *.PDF file in addition to the configuration file (*.EMB). XX Please check the settings on the real control unit! The following settings are not saved in the *.EMB file and must be adapted manually: àà PM: Battery size and number of PMEs àà WM: Sensors and wind thresholds àà CM: Maintenance time and time àà Password 11 General information … s) Response time to a control command (for cascading of the DMs with several drives with high switch-on peak currents) 0..2,50 s (Standard: 0,10 s) 10..3600 s (Standard: 300 s) Voltage-free phase during changeover. Note: àà The switch-on delay serves to map delayed sequence control. Maximum operating period for a drive line following a switching command. This time applies for ventilation OPEN and CLOSE but not for an alarm. The drive line switch-off time for RESET-CLOSE cannot be set. Note: àà When in active movement time mode the drive line switch-off time should be set greater than the movement time. … .4 Signalling ventilation signals (venting groups) As soon as a relay module is integrated in a control unit, additional configuration possibilities appear in the venting groups. Here, the statuses of the ventilation can be assigned to the relays. „Open“, „Close“ and „Stop“ are available for each relay. If parameters are set for a relay to display Open or Close, then Open or Close is active until there is either a change in direction of movement or a „Stop“ signal is issued. The stop signal is only pending when the system is stopped manually, i.e. àà Stop by pressing the Open/Close push buttons at the same time, àà Stop by active function „Start/Stop Open/Close push button“ or àà Stop by active biased-off function 39 ERM relay module MBZ 300 Configuration Software àà Automatic switch-off by the drive is not registered as „Stop“. àà Important note: This is an indicator of ventilation signals – not window statuses! Only the vent switch signals are shown. The opening of windows by alarm or closing by alarm resetting is not shown. àà Tip: A real window position can only be mapped by end position contacts (e.g. Reed contacts).
… map several control units connected via CAN-bus. (This function only becomes effected when the “Networked control units” program version is used.) Delete selection Deletes the module selected in the list Delete all Apply to SW config Deletes all the modules from the list Loads the list as system set-up into the configuration program. When configuration has been completed it can be saved (*.MBZ) in order to be exported to an actually existing control unit locally at a later date. The configuration file of an actually existing system can also be loaded into an identical, emulated system. The configuration can only be loaded to an identical control unit (same module sequence). The set-up must be known. Tip: Always save the *.PDF file in addition to the configuration file (*.MBZ). XX Please check the settings on the real control unit! The following settings are not saved in the *.MBZ file and must be adapted manually: àà PM: Battery size and number of PMEs àà WM: Sensors and wind thresholds àà CM: Maintenance time and time àà Password 11 General information … s) 10..3600 s (standard: 300 s) Voltage-free phase during changeover. Note: àà The switch-on delay serves to map delayed sequence control. Maximum operating period for a drive line following a switching command. This time applies for ventilation OPEN and CLOSE but not for an alarm. The drive line switch-off time for RESET-CLOSE cannot be set. MBZ 300 Configuration software … s. àà Tip: A real window position can only be mapped by end position contacts (e.g. reed-contacts) 43 Fire sections MBZ 300 Configuration software
… map several control units connected via CAN-bus. (This function only becomes effected when the “Networked control units” program version is used.) Delete selection Deletes the module selected in the list Delete all Apply to SW config Deletes all the modules from the list Loads the list as system set-up into the configuration program. When configuration has been completed it can be saved (*.MBZ) in order to be exported to an actually existing control unit locally at a later date. The configuration file of an actually existing system can also be loaded into an identical, emulated system. The configuration can only be loaded to an identical control unit (same module sequence). The set-up must be known. Tip: Always save the *.PDF file in addition to the configuration file (*.MBZ). XX 12 Please check the settings on the real control unit! The following settings are not saved in the *.MBZ file and must be adapted manually: àà PM: Battery size and number of PMEs àà WM: Sensors and wind thresholds àà CM: Maintenance time and time àà Password MBZ 300 Configuration software … s) 10..3600 s (standard: 300 s) Voltage-free phase during changeover. Note: àà The switch-on delay serves to map delayed sequence control. Maximum operating period for a drive line following a switching command. This time applies for ventilation OPEN and CLOSE but not for an alarm. The drive line switch-off time for RESET-CLOSE cannot be set. Runtime mode [] Runtime The maximum ventilation stroke can be limited with this option activated (“gap ventilation”). A “Ventilation OPEN” command activates the drive line in OPEN direction. The line stops automatically after the set “opening time”. A further “Ventilation OPEN” command is then ignored. Operation can also be stopped during movement. A further OPEN command then only activates the line for the residual time. The runtime is ignored in the alarm case. Runtime in OPEN direction: 0...1799 s (standard: 60 s) … s. àà Tip: A real window position can only be mapped by end position contacts (e.g. reed-contacts) 45 ERM relay module MBZ 300 Configuration software