Search filter

122 results found

Installation drawing

0100 Treibstangen F1200 Vertikal 50712-EP-0100 TU2+ZZ b= 1801

Download (.PDF | 25 KB)
Product data sheet

Product data sheet Link arm ECturn AREAS OF APPLICATION Single leaf swing doors Transom installation on opposite hinge side or door leaf installation on hinge side Reveal depth … - 200 mm For transom installation on opposite hinge side or door leaf installation on hinge side for reveal depths of … - 200 mm AREAS OF APPLICATION Single leaf swing doors Transom installation on opposite hinge side or door leaf installation on hinge side Reveal depth … - 200 mm GEZE GmbH Reinhold-Vöster-Straße 21–29 D-71229 Leonberg TEL +49 7152 203-0 2026-08-22T03:09:26Z WEB www.geze.de Mail info.de@geze.com Product data sheet | Page … of … Link arm ECturn PRODUCT FEATURES Colour silver or according to RAL Reveal depth with variable adjustment TECHNICAL DATA Productname Link arm ECturn VARIANTS / ORDER INFO Designation Description Ident-No. EAN Colour Link arm ECturn for reveal depth 90-200 mm 134664 4042938346641 silver-coloured Link arm ECturn for reveal depth 0-100 mm 134663 4042938346634 silver-coloured Link arm ECturn * for reveal depth 90-200 mm 135933 4042938359337 according to RAL Link arm ECturn * for reveal depth 0-100 mm 135932 4042938359320 according to RAL GEZE GmbH Reinhold-Vöster-Straße 21–29 D-71229 Leonberg TEL +49 7152 203-0 2026-08-22T03:09:26Z WEB www.geze.de Mail info.de@geze.com

Download (.PDF | 413 KB)
Product data sheet

0100 mm according to RAL ACCESSORIES ADAPTER FOR SENSOR LINK ARM For mounting the link arm at the same height as the sensor strip Designation Description Ident-No. EAN Colour Adapter for sensor link arm For Powerturn, EMD / EMD-F and TSA 160 NT 144352 4042938443524 silver-coloured Adapter for sensor link arm * For Powerturn, EMD / EMD-F and TSA 160 NT 153126 4042938531269 according to RAL GEZE GmbH Reinhold-Vöster-Straße 21–29 D-71229 Leonberg TEL +49 7152 203-0 2026-08-22T03:14:19Z WEB www.geze.de Mail info.de@geze.com Product data sheet | Page

Download (.PDF | 429 KB)
Product data sheet

Product data sheet Link arm Slimdrive EMD AREAS OF APPLICATION Single and double leaf swing doors Transom installation on the opposite hinge side Fire protection doors permitted untilreveal depth of 250 mm For transom installation on opposite hinge side for reveal depths of … - 400 mm AREAS OF APPLICATION Single and double leaf swing doors Transom installation on the opposite hinge side Fire protection doors permitted untilreveal depth of 250 mm GEZE GmbH Reinhold-Vöster-Straße 21–29 D-71229 Leonberg TEL +49 7152 203-0 2026-08-22T03:18:40Z WEB www.geze.de Mail info.de@geze.com Product data sheet | Page … of … Link arm Slimdrive EMD PRODUCT FEATURES Colour silver or according to RAL Reveal depth with variable adjustment TECHNICAL DATA Productname Link arm Slimdrive EMD VARIANTS / ORDER INFO Designation Description Ident-No. EAN Colour Link arm Slimdrive EMD * for Slimdrive EMD / EMD-F, reveal depth 200-300 mm 144389 4042938443890 silver-coloured Link arm Slimdrive EMD * for Slimdrive EMD / EMD-F, reveal depth 0-100 mm 144383 4042938443838 according to RAL Link arm Slimdrive EMD for Slimdrive EMD / EMD-F, reveal depth 0-100 mm 144381 4042938443814 silver-coloured Link arm Slimdrive EMD * for Slimdrive EMD / EMD-F, reveal depth 200-300 mm 144391 4042938443913 according to RAL Link arm Slimdrive EMD * for Slimdrive EMD / EMD-F, reveal depth 100-200 mm 144387 4042938443876 according to RAL Link arm Slimdrive EMD * for Slimdrive EMD / EMD-F, reveal depth 100-200 mm 144385 4042938443852 silver-coloured Link arm Slimdrive EMD * for Slimdrive EMD / EMD-F, reveal depth 300-400 mm 144395 4042938443951 according to RAL Link arm Slimdrive EMD for Slimdrive EMD / EMD-F, reveal depth 300-400 mm 144393 4042938443937 silver-coloured ACCESSORIES ADAPTER FOR SENSOR LINK ARM For mounting the link arm at the same height as the sensor strip Designation Description Ident-No. EAN Colour Adapter for sensor link arm For Powerturn, EMD / EMD-F and TSA 160 NT 144352 4042938443524 silver-coloured Adapter for sensor link arm * For Powerturn, EMD / EMD-F and TSA 160 NT 153126 4042938531269 according to RAL GEZE GmbH Reinhold-Vöster-Straße 21–29 D-71229 Leonberg TEL +49 7152 203-0 2026-08-22T03:18:40Z WEB www.geze.de Mail info.de@geze.com Product data sheet | Page … of … Link arm Slimdrive EMD * The products designated above may vary in form, type, characteristics, function, or availability depending on the country. Please get in touch with your GEZE contact person if you have any questions. GEZE GmbH Reinhold-Vöster-Straße 21–29 D-71229 Leonberg TEL +49 7152 203-0 2026-08-22T03:18:40Z WEB www.geze.de Mail info.de@geze.com

Download (.PDF | 434 KB)
Wiring diagram

0100-600 oder die länderspezifischen Vorschriften beachten. XX Als netzseitige Trennvorrichtung einen bauseitigen 2-poligen Leistungsschutzschalter (Überspannungskat. III) mit Verrieglungsmöglichkeit verwenden. XX Nach dem Einbau muss der gesamte Klemmenbereich abgedeckt sein. Nur so ist das Gerät ausreichend gegen unzulässiges Berühren spannungsführender Teile geschützt. 230V AC L1i L2h N 230 V AC 24V A 24V B Signal LIN 230V AC GND +24V L1-N +24V GND L2-N DANGER! Danger of electric shock! Before working on the electrical system interrupt the power supply, secure it against being switched on again and verify the safe isolation from supply. Wiring diagram Notes on electrical connection: XX The cabling must be carried out in such a way that there is sufficient clearance (> 20 mm) between input and output line and the power line and output line are laid separately XX Always use wire-end ferrules for wire cores XX Insulate wires that are not used XX Wiring diagram of the 24V window drives has to be considered. At 24 V DC and with long supply cable, the cable must have a sufficiently large cross-section to prevent voltage drop. Calculate cross-section! Connection terminals 24 V DC, 2,5 A ∓ ± EN Wiring diagram NT 2,5 A-24 V SM DIR EN Power supply NT 2,5 A-24 V SM DIR 230V AC 195297-01 NT 2,5 A-24 V SM DIR power supply Technical data ID 195293 Mains voltage 220 - 240 V AC +/-10% Mains frequency 50-60 Hz Input current 0,58 A Idling input power 0,24 W Output power 60 W Output voltage 24 V DC ±5% (SELV) Output current 2,5 A, ED 30%, … 95% max. installation height a.s.l. 2000 m IP rating IP 20 Protection rating II Standard EN60335-1 Application area dry rooms Connection cross-section 1,5 mm² Dimensions (LxWxH) 200 x 50 x 25 mm Group control max. 10 power supplies can be connected in parallel (230 V) Max. cable length switch ↔ power supply (230V) 50 m Application The NT 2,5 A-24 V SM DIR power supply is a controlled power supply designed for use in the one-phase AC network. It has an integrated direction control for the operation of 24 V window drives. The running direction of the drives is determined by the polarity of the supply voltage. It serves as a power supply for GEZE 24 V window drives. Perfect and safe device operation requires adequate transport, proper storage, assembly and installation. DANGER! LTA-LSA (ID: 118476) Danger of electric shock! During the operation of electrical devices, certain parts are always energised with hazardous voltage. Improper use of these devices can thus lead to death or serious physical injuries as well as to considerable property damage. Safety instructions XX Always have the connection set up by a qualified electrician. XX This supplementary sheet must always be read before installation. XX Heed the relevant standards and regulations, in particular DIN VDE 0100-600 or country-specific regulations. XX As a line-side disconnecting device, use an on site 2-pole circuit breaker (overvoltage cat. III) with locking possibility. XX The entire connector area must be covered after installation. This is the only way to protect the device sufficiently against impermissible contact with live parts. XX Before the system is released for operation, an insulation measurement of the system's line network must be performed and logged. 230V AC 24V A 24V B Signal LIN 230V AC GND +24V L1-N +24V GND L2-N L1i L2h N 230 V AC

Download (.PDF | 1 MB)
Installation instructions

0100 20 10 130 F 1200 24 CL CL + Z Z Ø 4,2 10 M5 x 16-H ISO 7046-1 M5 x 20 DIN 965 M5 x 30 DIN 966 M5 x 30 ISO 746-1 … 50712-EP-0100 20 10 191270

Download (.PDF | 10 MB)
Wiring diagram

0100-610. àà Observe the latest versions of guidelines, standards and countryspecific regulations. DE Beiblatt EN Supplementary sheet XX The IQ box KNX must be protected from building dirt and water. XX The IQ box KNX is a product of the KNX systems and detailed specialist know-how gained through KNX training is required for the product to be understood. 165786-01 Kurzbeschreibung / Short description Technische Daten / Technical data Die IQ box KNX ermöglicht das Steuern und Überwachen der GEZE IQ windowdrives (Slimchain, Powerchain etc.) über das KNX-Bus-System. Die Antriebe können auf gewünschte Positionen gefahren werden und es können die aktuelle Antriebsposition und diverse Zustände des Antriebs abgefragt werden. Zwei zusätzliche Eingänge können entweder für den Direktbetrieb (z.B. Handtaster) oder als Bus-Eingänge verwendet werden. Die Konfiguration erfolgt mit der KNX-Software ETS (ab Version … +70°C Anschlussquerschnitt 24 V-Versorgung und Antriebe / Connection cross-section 24V supply and drives Anschlussquerschnitt Eingänge/Taster / Connection cross-section push buttons max. 1,5 mm² Anschluss KNX-Bus / KNX-bus connection KNX-Anschlussklemme rot/ schwarz / KNX supply terminal red/ black 30 m Max. Leitungslänge Taster / Max. cable length for push button max. 1,5 mm² Max. Gesamtleitungslänge Antriebe (LIN-BUS) / Max. overall cable length for drives (LIN-BUS) 50 m Maße / Dimensions 98 mm x 62 mm x 18 mm Montageort / Mounting location Aufputz- oder Unterputzgehäuse. Montage auf 35 mm-Hutschiene / Surface-mounted or flush mounted housing. For mounting on a 35 mm top hat rail àà Sicherstellen dass der Anschluss an die Netzspannung nur von einer Elektrofachkraft durchgeführt wird. Netzanschluss und Schutzleiterprüfung müssen entsprechend DIN VDE 0100-610 *) SELV = Sicherheitskleinspannung / Safety extra-low voltage Elektrischer Anschluss / Electrical connection Anschlussplan IQ windowdrives ID 148327 beachten ! Nur verwendbar mit GEZE IQ windowdrives ab Software

Download (.PDF | 641 KB)
Wiring diagram

0100-610. àà Observe the latest versions of guidelines, standards and countryspecific regulations. DE Beiblatt EN Supplementary sheet XX The IQ box KNX must be protected from building dirt and water. XX The IQ box KNX is a product of the KNX systems and detailed specialist know-how gained through KNX training is required for the product to be understood. 164448-01 Kurzbeschreibung / Short description Technische Daten / Technical data Die IQ box KNX ermöglicht das Steuern und Überwachen der GEZE IQ windowdrives (Slimchain, Powerchain etc.) über das KNX-Bus-System. Die Antriebe können auf gewünschte Positionen gefahren werden und es können die aktuelle Antriebsposition und diverse Zustände des Antriebs abgefragt werden. Zwei zusätzliche Eingänge können entweder für den Direktbetrieb (z.B. Handtaster) oder als Bus-Eingänge verwendet werden. Die Konfiguration erfolgt mit der KNX-Software ETS (ab Version … ). The product database and detailed technical descriptions are available for downloading from the website www.geze.com. Sicherheitshinweise / Safety instructions Für die Sicherheit von Personen ist es wichtig, diesen Anweisungen Folge zu leisten. Diese Anweisungen sind aufzubewahren! àà Vor Montage beiliegende Sicherheitshinweise lesen und beachten! Gewährleistungsansprüche setzen eine fachgerechte Montage, Installation und Wartung nach den Angaben des Herstellers voraus. àà Nur Sachkundige dürfen Montage, Inbetriebnahme und Wartung durchführen. Eigenmächtige veränderungen an der Anlage schließen jede Haftung von GEZE für resultierende Schäden aus. àà Für Reparatur- und Wartungsaufgaben nur GEZE-Originalteile verwenden. àà Sicherstellen dass der Anschluss an die Netzspannung nur von einer Elektrofachkraft durchgeführt wird. Netzanschluss und Schutzleiterprüfung müssen entsprechend DIN VDE 0100-610 Versorgungsspannung IQ box KNX und Antriebe / 24 V DC, +-25%, SELV *) Supply voltage IQ box KNX and drives Max. Strom Antriebe / max. current drives 6A Eigenstromaufnahme an KNX-Bus Induced current intake to KNX-bus

Download (.PDF | 585 KB)
Installation instructions

0100-610 durchführen. àà Als netzseitige Trennvorrichtung einen bauseitigen 10-A-Sicherungsautomaten verwenden, der die Anlage vom Netz trennt. àà Gemäß der Maschinenrichtlinie 2006/42/EG und der DIN 18650 muss vor Inbetriebnahme der Türanlage eine Sicherheitsanalyse (Gefahrenanalyse) durchgeführt werden und die Türanlage gemäß CE-Kennzeichnungsrichtlinie 98/68/EWG gekennzeichnet werden. àà Den neuesten Stand von Richtlinien, Normen und länderspezifischen Vorschriften beachten, insbesondere: - BGR 232 „Richtlinien für kraftbetätigte Fenster, Türen und Tore“ - DIN 18650 „Schlösser und Beschläge - Automatische Türsysteme“ - DIN VDE 0100-610 „Errichten von Niederspannungsanlagen“ - DIN EN 60335-2-103 „Sicherheit elektrischer Geräte für den Hausgebrauch und ähnliche Zwecke; Besondere Anforderungen für Antriebe, für Tore, Türen und Fenster“ - Unfallverhütungsvorschriften, insbesondere BGV A1 „Allgemeine Vorschriften“ und BGV A3 „Elektrische Anlagen und Betriebsmittel“ àà Operating, maintenance and repair conditions specified by GEZE must be observed. àà The commissioning, prescribed installation, maintenance and repair work must be performed by properly trained personnel authorised by GEZE. àà GEZE shall assume no liability for damage caused by unauthorised changes to the system. àà The owner is responsible for safe operation of the system. If safety equipment is misaligned, causing it to no longer fulfil its intended purpose, further operation is not permissible. Inform the service technician immediately in this case. àà GEZE shall not be liable if products from other manufacturers are used with GEZE equipment. Only original GEZE parts may be used for repair and maintenance work as well. àà The connection to the power supply must be made by a professional electrician. Perform the power connection and safety earth conductor test in accordance with DIN VDE 0100-610. àà Use a customer-accessible 10-A overload cut-out that disconnects the system from the power supply as the line-side disconnecting device. àà In accordance with Machinery Directive 2006/42/EC and DIN 18650, a risk analysis must be performed and the door system identified in accordance with CE Identification Directive 98/68/EEC before commissioning the door system. àà Observe the latest versions of guidelines, standards and country-specific regulations, in particular: - BGR 232 “Guidelines for power-operated windows, doors and gates“ - DIN 18650 “Building hardware - Powered pedestrian doors“ - DIN VDE 0100-610 “Installation of low-voltage systems“ - DIN EN 60335-2-103 “Safety of electrical devices for home use and similar purposes; special requirements for drives for gates, doors and windows“ - Accident-prevention regulations, especially BGV A1 “General regulations“ and BGV A3 “Electrical systems and equipment“

Download (.PDF | 2 MB)
Cable plan

0100 · Cable routing, connection and initial operation may only be carried out by authorised specialists. · GEZE will not assume any warranty or provide service if GEZE products are combined with third-party products. · The wiring diagram is only a schematic representation. The exact routing of the cables must be determined on site. · All cable and water connections of the hot-air curtain system must be laid by a specialist company on site.

Download (.PDF | 1 MB)